Reports until 17:50, Thursday 04 October 2012
H1 SUS
stuart.aston@LIGO.ORG - posted 17:50, Thursday 04 October 2012 - last comment - 12:47, Friday 05 October 2012(4380)
H1SUSMC2 model rt net stat error reported?
I noticed on the H1SUSMC2_GDS_TP screen a "red" status under the first (of four) elements for the "RT NET STAT". All other SUS models are "green".

Reported to Jim Batch to look into...
Comments related to this report
stuart.aston@LIGO.ORG - 12:47, Friday 05 October 2012 (4385)
Dave B informed us that it is likely triggered and then latched when the model is started. "Diag Reset" clears the error condition. 
H1 SEI
greg.grabeel@LIGO.ORG - posted 17:09, Thursday 04 October 2012 - last comment - 16:29, Monday 08 October 2012(4378)
HAM1 HEPI Spring adjustment
After HAM1 needed a large  movement  to rectify some measurement issues the springs had come into hard contact with the side of the housing collar. I re-centered the springs and loaded the weight back to the previous values. This brought the support tubes to +- 25 thousandths of an inch. During the process of bringing the support tubes to nominal one of the springs started to bind, and after removing the nut one could see several demolished threads. Tyler G. expertly repaired them and I replaced the spring. 

The support tubes are now sitting within +- 5 thousandths although with the amount of activity around the dial indicators some of those values may be adulterated. After I locked the HEPI feet down I re-zeroed the dial indicators and hopefully placed them in better positions for when IAS can shoot the table.
Images attached to this report
Comments related to this report
greg.grabeel@LIGO.ORG - 16:29, Monday 08 October 2012 (4398)
There was some concern about the threads of the spring. The threads were cleaned up on the lathe knocking out the material that had been deposited in the root of the thread. This added a bit of slop where some crests had been lost but I flipped the spring in the housing so the areas supporting the tension of the spring are on good threads. 
Images attached to this comment
X1 SUS
stuart.aston@LIGO.ORG - posted 17:06, Thursday 04 October 2012 (4379)
Channels Added to Triple Test-Stand
To enable the more automated Matlab TFs to be taken on the LHO triple test-stand, I have added the following channels (and corresponding data rates) to the channel list:-

X1:SUS-HXTS_M1_TEST_L_OUT_DQ 2048
X1:SUS-HXTS_M1_TEST_T_OUT_DQ 2048
X1:SUS-HXTS_M1_TEST_V_OUT_DQ 2048
X1:SUS-HXTS_M1_TEST_R_OUT_DQ 2048
X1:SUS-HXTS_M1_TEST_P_OUT_DQ 2048
X1:SUS-HXTS_M1_TEST_Y_OUT_DQ 2048

These have been added to the *.ini files of both models i.e. "X1SUSHXTS05.ini" and "X1SUSHXTS27.ini".

After logging into the test-stand front-end "ssh tripleteststand", the frame-builder has been restarted by switching models using the script "useModel27", waiting a 60 seconds, then finally returning back to the required model "useModel05". 

Running the "LHOTripleTFs.m" Matlab script from the "susSVN/trunk/Common/MatlabTools/SchroederPhaseTools" directory, now successfully extracts the above channels from the frame data.
H1 ISC
filiberto.clara@LIGO.ORG - posted 16:17, Thursday 04 October 2012 (4377)
ISC Cabling Installation
Worked on cable installation in electronics room racks ISC-C3 and ISC-C4. While powering up electronics in ISC-C4, connected ±18V backwards to either:

D1002735 Harmonics Generator Power Supply - SN S1000791 or
D1000124 RF Distribution Amplifier - SN S1000604

Units seem to be powering up, but will look closer once testing begins.

Filiberto Clara
LHO General
gerardo.moreno@LIGO.ORG - posted 16:10, Thursday 04 October 2012 (4376)
Operator Summary

I was notified of the following activities:

Received several (4 of them) dust alarms from the dust monitor moved by Patrick to the cleanroom for the test stand (West bay, north most test stand).

Two PSL alarms.

H1 INS
jodi.fauver@LIGO.ORG - posted 15:16, Thursday 04 October 2012 (4374)
BSC8 De-Install/BSC1 Install Prep
First thing this morning, the Apollo crew raised the chamber cleanroom back up to its usual working height and removed the lower portion of the leg jacks. Next, they craned the dome back over to the BSC. The walking plates were removed and the dome was re-installed with all bolts in place. Once the dome was in place, Thomas supervised the removal of ACB parts from the chamber to a large C-3 covered work table. The ACB parts were covered with C-3 and transported to the HAM cleanroom for dis-assembly. After much discussion, the BSC flooring was removed from the chamber, preserved clean, and transported to the HAM cleanroom for Wrap-Bag-Tag. The door was returned to the chamber. (Not bad for a day's work!)

While Mark L. was in-chamber to retrieve the BSC flooring, he surveyed the chamber bottom for detritus after the flooring was removed: this is our SOP when doing ICC. This chamber has the potential to be quite instructive WRT contamination issues because we have very sharp data points for length of exposure and type of activity. The highlights (or low-lights, as the case may be): two relatively large pieces of UHV foil, at least three human hairs, and lots of Al fines. See a few pix below.
Images attached to this report
H1 ISC
keita.kawabe@LIGO.ORG - posted 15:11, Thursday 04 October 2012 (4375)
HAM3 IO/ISC ground loop check done

Checked DB25 connectors for IO QPD , ISC QPDs and IO/ISC picos and they're all fine. Measured from outside, no shortcircuit  between pin13 and vacuum chamber.

H1 SUS
stuart.aston@LIGO.ORG - posted 12:51, Thursday 04 October 2012 (4372)
MC2 (HSTS) Phase 3a M1-M1 damped and un-damped TFs, plus power spectra
Firstly, a set of MC2 (HSTS) M1-M1 TFs were taken, with damping loops OFF, for all DOFs (see 2012-10-03_H1SUSMC2_M1_ALL_TFs.pdf), which show good agreement with the model. These TFs were then repeated, but with damping loops ON.  

Both damped and undamped TFs obtained have been compared to all other LLO HSTSs at the equivalent test Phase 3a, (see allhstss_2012_10_04_Phase3a_MC2_ALL_ZOOMED_TFs.pdf). 

Power spectra have been taken with damping loops both ON and OFF for each stage (see 2012-10-04_1000_H1SUSMC2_M*_ALL_Spectra.pdf).

Power spectra data, with both damping ON and OFF can then be compared to LLO MC2 during Phase 3a testing (see allhstss_2012-10-01_Phase3a_MC2_ALL_Spectra_Don.pdf and allhstss_2012-10-01_Phase3a_MC2_ALL_Spectra_Doff.pdf). n.b. the purge-air was off for the LLO measurements. 

In addition, power spectra for specific degrees of freedom (L, P and Y) can be more conveniently compared across multiple stages (M1, M2 and M3) of the same suspension in the final plot found below (see allhstss_2012-10-01_Phase3a_MC2_H1SUSMC2_M1M2M3_Spectra_ALL_Don.pdf).

Finally, all data, plots and scripts have been committed to the susSVN as of this entry.

This should now provide sufficient data to be able to complete Phase 3a testing of this suspension
Non-image files attached to this report
H1 SUS
stuart.aston@LIGO.ORG - posted 12:48, Thursday 04 October 2012 (4373)
PR2 (HSTS) Phase 3a M1-M1 damped and un-damped TFs, plus power spectra
Firstly, a set of PR2 (HSTS) M1-M1 TFs were taken, with damping loops OFF, for all DOFs (see 2012-10-03_H1SUSPR2_M1_ALL_TFs.pdf), which show good agreement with the model. These TFs were then repeated, but with damping loops ON.  

Both damped and undamped TFs obtained have been compared to all other LLO HSTSs at the equivalent test Phase 3a, (see allhstss_2012_10_04_Phase3a_PR2_ALL_ZOOMED_TFs.pdf). 

Power spectra have been taken with damping loops both ON and OFF for each stage (see 2012-10-04_1015_H1SUSPR2_M*_ALL_Spectra.pdf).

Power spectra data, with both damping ON and OFF can then be compared to LLO PR2 during Phase 3a testing (see allhstss_2012-10-01_Phase3a_PR2_ALL_Spectra_Don.pdf and allhstss_2012-10-01_Phase3a_PR2_ALL_Spectra_Doff.pdf). n.b. the purge-air was off for the LLO measurements. 

In addition, power spectra for specific degrees of freedom (L, P and Y) can be more conveniently compared across multiple stages (M1, M2 and M3) of the same suspension in the final plot found below (see allhstss_2012-10-01_Phase3a_PR2_H1SUSPR2_M1M2M3_Spectra_ALL_Don.pdf).

Finally, all data, plots and scripts have been committed to the susSVN as of this entry.

This should now provide sufficient data to be able to complete Phase 3a testing of this suspension. 
Non-image files attached to this report
H1 IOO
rodica.martin@LIGO.ORG - posted 08:14, Thursday 04 October 2012 (4371)
H1 FI high power testing in PSL

Yesterday Cheryl and I started working on H1 Faraday high power testing in the PSL. We checked the alignment and mounted power meters for isolation, transmission and REFL measurements. We picked off about 1% of the transmitted beam for thermal lens measurements and placed several beam dumps to catch stray beams. 

Rick S and Michael R connected for us another high-power water-cooled power meter to a second chiller (thank you!). Cheryl mounted a beam block to catch the AR beam from the first IO mode matching lens to IMC (IO_MB_L1), which was previously resting on a dog clamp next to the EOM case.

Images attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 22:05, Wednesday 03 October 2012 (4370)
plots of dust counts for October 2, 2012
Attached are plots of dust counts > .3 microns and > .5 microns in particles per cubic foot. The data was taken from approximately 6 AM to 9 PM. Also attached are plots of the modes to help show when they were running.
Non-image files attached to this report
LHO General
patrick.thomas@LIGO.ORG - posted 21:45, Wednesday 03 October 2012 (4369)
plots of dust counts
Attached are plots of dust counts > .3 microns and > .5 microns in particles per cubic foot. The data was taken from approximately 6 AM to 9 PM. Also attached are plots of the modes to help show when they were running.
Non-image files attached to this report
H1 SUS
stuart.aston@LIGO.ORG - posted 16:50, Wednesday 03 October 2012 (4365)
HAM3 PR2 and MC2 B&K Hammer Measurements
[Stuart A, Betsy B and Travis S]

Following the installation of PR2 (HSTS) and MC2 (HSTS) suspensions into the HAM3 chamber, and confirming that the optics were freely suspended, by running un-damped M1-M1 Matlab TFs (available in LHO aLOG entry 4353), B&K hammer measurements could then commence in-chamber.  

Both PR2 and MC2 suspensions were fully dog-clamped down, and torqued to the requirement. 

The tri-axial accelerometer was attached using an interface plate, to a horizontal strut near the top of each of the structures, i.e. the opposite side to where the vibration absorbers are fitted.

For convenience, the axes of the accelerometer were aligned with the axes of the suspension (i.e. X = longitudinal, Y = transverse, Z = vertical). The hammer was used in two places to excite the structure, the first being +X at the front of the structure, and the second being +Y on the side of the structure.

Image #554 below shows the LLO PR2 structure, with the accelerometer installed.
Image #547 below shows the LLO PR2 structure, with the impact hammer locations highlighted.
Image #2338 below shows the LHO HAM3 B&K hammer measurement set-up (PR2 in foreground, MC2 in background).

Measurements were taken using the "simple hammer display 3.pls" template available in T1000697. A hammer trigger threshold of approximately 40N was found to work best in all cases. 

For PR2, measurements were initially taken without vibration absorbers fitted, and then repeated after installation of the vibration absorbers. 

However, for MC2, vibration absorbers had already been installed, and it was deemed too much of a risk (handling & contamination concerns) to remove them. So in this case, B&K measurements proceeded on MC2 with the vibration absorbers already fitted. 

B&K hammer measurements have been taken for the following conditions (each corresponding raw data-set available below):-

PR2 - Test 1a - VA not fitted - SUS unlocked - (SIDE HIT)
PR2 - Test 1b - VA not fitted - SUS unlocked - (FRONT HIT)
PR2 - Test 2a - VA fitted - SUS unlocked - (SIDE HIT)
PR2 - Test 2b - VA fitted - SUS unlocked - (FRONT HIT)

MC2 - Test 3a - VA fitted - SUS unlocked - (SIDE HIT)
MC2 - Test 3b - VA fitted - SUS unlocked - (FRONT HIT)

The raw data has been exported from the B&K pulse analysis software and into an excel spreadsheet for comparing and plotting. The spreadsheet and a merged pdf of relevant plots are available below.

On PR2, the effect of the vibration absorbers in damping the first and second resonance modes is clearly visible. The first resonance peak also drops from ~94Hz down to ~89Hz.

For MC2, the first resonance peak is visible at ~91Hz. 
Images attached to this report
Non-image files attached to this report
H2 SEI
hugh.radkins@LIGO.ORG - posted 16:25, Wednesday 03 October 2012 (4368)
WBSC8 ISI/ITM/FMY Cartridge is out of Chamber and on Test Stand
No real issues here, took plenty of time, balancing the lift, lowering the cleanroom, positioning the Cartridge over the Test Stand.  Dale took lots of photos, I'm sure he'll log soon.
Thanks to Jim & Mitchell and the Apollo Crew Randy, Chris, Mark, Ed, Scott & Bubba.
H1 ISC
corey.gray@LIGO.ORG - posted 16:15, Wednesday 03 October 2012 (4367)
H1 ISC/IO Table Work

Keita and I installed the Hepa Filter on top of the ISCT1 Enclosure and we craned this enclosure on top of the cleaned table (Ameristat is now removed).  The Enclosure is not secured onto the table.

While we were at it, we installed the Hepa Filter on the IOT2R (small).  The remainder of the Hepa filters have been stored at MY (for H1) & will (or have been) be stored in the Mechanical Room for India.

Removed all the iLIGO optics off the future ISCT6 & ALS-EX tables (all these optics are "stored" on the aLIGO IOT2L---lots of inventorying to do!!).  Periscopes are on the floor outside of the Squeezer area.

H1 SUS
betsy.weaver@LIGO.ORG - posted 16:03, Wednesday 03 October 2012 (4366)
HAM3 work

Today, we finished the B&K Hammer measurements on PR2 and MC2.  We also finalized the cable routing (more like threading) between the IO and ISC multitude of small mirror mounts and sled, adding more metal cable straps to hold everything down to the table surface nicely.  SUS really just needs to remove FC and inspect/cleanup the optics before closing out this chamber.  IO and ISC may have more work...

LHO General
james.batch@LIGO.ORG - posted 15:02, Wednesday 03 October 2012 (4364)
Control Room Computer Changes
The workstations on the left side of the control room (as you face the screens) have been converted to be used for h1.  Also, the video screens on the left side are all now assigned for h1 displays.
H2 CDS
david.barker@LIGO.ORG - posted 09:26, Wednesday 03 October 2012 (4363)
various front ends restarted/rebooted to characterize mx_streams problem

Tuesday morning maintenance:

In an attempt to characterize the mx-streams issue (a front end is restarted/rebooted and all DAQ data from all front ends becomes bad), I made a variety of model restarts and front end computer power cycles using the following front ends:

h2susauxb478, h2pemeyaux, h2seib8, h2susb78, h2susb478.

Unfortunately I was unable to reproduce the problem.

LHO General
james.batch@LIGO.ORG - posted 08:09, Wednesday 03 October 2012 (4362)
New webview scripts installed.
New webview scripts have been installed to automatically capture the currently built models for h1 and h2.  This new script allows read-only examination the current models from anywhere using a web browser, no matlab needed.  The current version treats model parts as links, so one can easily examine the hierarchy of the models.  The script has been adapted from one used at LLO, modified to handle two IFOs.
LHO General
james.batch@LIGO.ORG - posted 08:00, Wednesday 03 October 2012 (4361)
New version of awgstream installed for control room computers
A new version of awgstream has been installed for control room computers for Ubuntu and OS X.  This version is for a bug fix that involves obtaining a channel list when the list has grown longer than a built-in limit.  The new code should solve this, at least until the list becomes so long that no storage can hold it!