With the arm cavity locked I tried to measure again the WFS sensing matrix. It still looks almost degenerate in both PIT and YAW.
These are the measurements:
sensP =
1.0e-03 *
-0.2374 0.2929
-0.1506 0.1611
sensY =
1.0e-03 *
0.0133 -0.1897
0.0177 -0.2023
And these are inverted matrices:
iP =
1.0e+04 *
2.7373 -4.9782
2.5596 -4.0341
iY =
1.0e+05 *
-2.9772 2.7915
-0.2610 0.1953
The measuremetns are at about 4 Hz.
They look quite bad. I won't even try to impelment them.
The arm cavity is stably locked since 23:15 UTC.
There is only damping enabled on the ISI. We turned the isolation off because it was causing the oscilaltions at few tens of mHz on the reflected power.
This is a summary of fine tuning the mode matching into the PMC for the 35W laser. The attached spreadsheet lists the power of each mode looking at ISS_PDA_DC hooked into an oscilloscope. The position of the lenses L2 and L3 is measured from the lens's block's edge facing HAM1. After moving a lens the alignment peak was minimized to below 10mV and was not included in this spreadsheet. Mode power is measured in mV and going to the 'right' of the 00 mode. The strongest peak is the last one (first to the 'left') and looks similar to a 11 Laguerre-gaussian mode. I believe the second mode listed is the 02 mode, however most are too faint to see clearly.
The best position appears to be
L2: 368mm
L3: 738mm
Note that this is very different for the 200W laser. For the 200W laser, the lenses are at:
L2: 310mm
L3: 728mm
I do not have other numbers for the 200W laser.
One-Arm Test yielded morning to "noisy" activities; goal was to have some cavity locking & Wavefront Sensor work later.
Apollo drilling for oplev piers in morning (and a little in the afternoon)
Giacamo/Cheryl: SUS AUX assembly work in LVEA (after lunch)
Hugh going to check BSC6 to look at HEPI (morning)
Alex going to EY optics lab to inventory TMS (morning)
Bubba squaring up main crane by hitting bumpers, but this activity ended up tripping/deactivating the crane. Will be investigated in the morning (manlift required)
Scotty doing some quick drilling (1:50-2:10)
Eric doing feedthru protection work (avoiding HAM3 due to OAT)
Keita at EY lab (left at 3:30)
The reference cavity has been locked continusously, with no glitches for about 24 hours. It's not clear why, since yesterday no one even touched the FSS.
Anyways, we're happy about that and we hope it'll last.
Attached is a 24 hr trend of the cavity transmitted power. On the left end you can see the glitches that we were having before.
35W beam
Andres and I ran the first set of transfer functions on H1-PRM yesterday. The results are posted in the attached files. There is a problem with P, R, and V. We are checking the suspension for EQ stops rubbing, OSEM alignment, and Flag positioning and will rerun the transfer functions after taking corrective action. The first set of transfer functions were taken in the afternoon with no one in the Triples Lab (where the suspension is located) and only light assembly work (no forklifts, moving BSC plates, etc) underway on the ground floor. As a test, I repeated taking the transfer functions last night after everyone had left the staging building for the night. There was no difference between the TFs taken during the day and at night. Conclusion: As long as the Triples Lab is empty and there is limited activity in the rest of the staging building, we should be able to test suspensions during normal working hours.
This morning at 14:11utc (7:11am Pacific time) a couple of earthquakes reached us. This tripped both BSC8 & BSC6 ISI & HEPI. The initial quake was a 6.8 (13:43utc) & the aftershock was 5.2 (13:51utc). Attached is a trace of one of the SEI Watchdogs (i.e. BSC8 ISI Stage1).
During a cavity scan, a second modulation is applied to the laser frequency. The response of a Fabry-Perot cavity to laser frequency modulation contains information about the cavity parameters, including cavity length, free spectral range, modal spacing, and the radius of curvature of the cavity optics. The goal of cavity scans is to measure cavity characteristics and characterize their time evolution in response to heating of the optics.
While the 532 nm ALS laser is locked to the arm cavity, laser frequency modulations are injected into the Innolight Prometheus frequency-doubled laser through the laser frequency servo (Common Mode A) with an SR785 signal analyzer. These frequency modulations are transmitted into the 1064 nm beam used for PSL phase locking and the 532 nm beam used for arm cavity locking. The PSL phase locking beam does not interact with the arm cavity, and the signal from the RF photodiode is used as a proxy for the signal injected into the arm cavity. The arm cavity reflection photodiode gives the output signal, which the SR785 divides by the input signal to produce a transfer function.
Automation of SR785 measurements is necessary to perform and store transfer functions in quick succession over a period of hours. A Prologix GPIB-Ethernet controller is used for remote control and retrieval of data from the SR785. Scripts for performing transfer functions and retrieving data using the GPIB-Ethernet interface were created for use at the 40m interferometer, and were used for cavity scan transfer functions here. The Python script exttt{TFSR785.py} performs a single transfer function.
A bash script, exttt{autoTF}, was used to repeatedly call this Python script. This script was originally set to perform one scan from 30kHz to 80kHz, alternate smaller scans around the first-order modes (from 46-47 kHz and from 65.75-66.75 kHz) three times, then repeat until 12 hours elapses or the script is terminated. During the scan, it was found that the first-order peaks moved further than anticipated, so the script was altered to scan from 45-46 kHz and 66.75-67.75 kHz. In future scans, the smaller scans will be run from 45-47 kHz and 65.75-67.75 kHz for the duration. For all scans, the amplitude of the excitation was 10 mV, and 10 averages were used.
The ALS laser output power is 100 mW, and the SR785 excitation output current is 100 mA. Therefore, the modulation depth for these cavity scans is 0.1, or 1% of power in the modulation sidebands.
The attachment cavity_characterization.pdf contains a more thorough explanation of the motivation behind cavity scans, and some preliminary results. The attachment cavityshift.pdf plots a cold cavity scan and a cavity scan after 2.5 hours of heating on the same axes, showing the shift in modal spacing with ITM heating.
H1-HSTS-PRM is ready for Phase 1b testing. OSEMs have been centered and tested. Check the attached file for data on Open Light Values, Offsets, Gains, etc.
Attached are plots of dust counts > .5 microns in particles per cubic foot.
Kyle, Gerardo (initial) The two leaking 16.5" feedthrough assebmlies were removed from BSC1. A custom bracket was fabricated and utilized which allowed the assemblies to be removed with the crane (as a whole unit). NOTE: Ports are covered in UHV foil but BSC1 is not within a cleanroom and is reliant on properly adjusted purge air - please don't adjust the Vertex Volume's purge air.
Found h2susb78 locked up as of 21:02:43 PDT Aug. 28. Restarted, models ran about 3 minutes and communication between IOC and computer went away (one-stop card/cable issue). The IOC one-stop card was replaced with a new revision C2 card yesterday, so suspecting an early failure, the IOC one-stop card was replaced with another one. With this second new one-stop card, one of the main PCIe buses was not visible to the computer, and the duotone timing was off by 35uS. Gave up, and installed an old non-updated one-stop card back in the IOC. System came up normally, but will have to run without problems for about 3 days before confidence begins to be restored.
Restarted test stands after timing system work. Restarted IOP models, but no user models. Applies to tripleteststand, bscteststand2, and seiteststand2.
[Alex, Deepak, Cheryl, Giacomo] Yesterday we finished alignment of the remaining 2 HAUX. All 4 are aligned and hooked up. The optical lever setup is in place, but no pitch balancing has been done yet. Electronics is up and running, the model has been restored to a clean working state after reboot, and BURT saved: - all OSEMs offsets and gains set - Damping filter set to (what I think are) reasonable values (no much though on this as of now: they just work to damp the optic) and set to the off state - Hardware LP filter set to ON (but see later) - Coils TEST enable flag set to 1. - Master switches are off Note that although the hardware for binary IO is on, apparently there is no state change when we change the flags in the software. It is not clear if status is not changed, or if is changed but not reported. This will need to be investigated this morning.
Added missing (Binary) cables in rack SUS-C3, from IO chassis (FE IO Chassis 2 HAM-A Controls) to Binary Input and Output Chassis. This only solved part of the issue, since the Enable and Disable bits were not switching. Opened up HAM A Coil Drivers and removed jumpers for Disable / Enable. With the jumpers in place, the state would not change regardless of input. No jumpers should be installed in P3 and P4. All four HAM-A Coil Drivers had the jumpers removed. S1201163 S1201160 S1201158 S1201161
Attached are plots of dust counts > .5 microns in particles per cubic foot.
Electronics were troubleshooted.
SEI and SUS models were arranged to allow un-tripping HAM2-ISI Payload Watchdogs.
HAM2 model was re-compiled, installed and re-started after that. It is now running.
Matrices were filled
Input and output filters are loaded
The latest version (Version_2) of the unit-specific control scripts were copied from LASTI. They were made ready for use on HAM2.
Spectra were taken on the ISI tilted. It is the worse configuration for GS13s and they all appear to be working fine (see attached plot).
Transfer function measurements are running overnight.
The transfer functions measured last night had features that are typical to mis-connected sensors/actuators. Deeper analysis allowed narrowing it down the the GS13s.
We made a program to check for "cross-coupling transfer functions" (e.g. drive on H1, response on H2). It revealed that:
H1-GS13 was read on the channel of H3-GS13
H2-GS13 was read on the channel of H1-GS13
H3-GS13 was read on the channel of H2-GS13
V1-GS13 was read on the channel of V3-GS13
V2-GS13 was read on the channel of V1-GS13
V3-GS13 was read on the channel of V2-GS13
We checked our model and did not find a cause for such behaviour there. We moved on the the electronics rack and spotted the issue: GS13 In-field cables were connected to the wrong inputs on HAM2 sensor interfaces.
We ran a quick TF measurement between 500mHz and 5Hz. It confirmed that the sensors were now all correctly connected. This quick measurement is also in good accordance with what we measured on HAM-ISIs in the past which is encourraging.
TF measurement are running overnight on HAM2. They will be over by 7am.
Note: A blinking notification was recently added to HAM-ISI overview MEDM screens (see attachement). It turns the green "measurement" button to blinking yellow when a TF is running. HAM2 overview screen can be seen on the Video6 monitor of the Control Room.
Hugh and I added screwdriver tips under the top payload mass of HAM2-ISI last week, before the chamber was closed. They helped prevent this big mass of ~600lbs from causing unwanted resonances. Befoire/After comparison plots are attached.
We compared the latest transfer functions with the ones taken on LLO HAM2-ISI during the same phase of testing (Intitial In-Chamber Testing). Plots are attached. Accordance is good. We are confident that the unwanted resonance seen at 96Hz comes from the top mass. We plan on ajusting its boundary conditions with the optical table once the doors of HAM2 chamber are open again.
It is a long way from being robust, and it is quite slow, but the cavity dither alignment worked this evening. The commands are:
YAW
./tdsdither 1.9 30 4 0 300 H2:SUS-ITMY_M0_TEST_Y_EXC H2:ISC-ALS_EY_REFL_PWR_MON_OUT H2:SUS-ITMY_M0_OFFSET_Y 10 5
./tdsdither 2.3 50 5 0 300 H2:SUS-ETMY_M0_TEST_Y_EXC H2:ISC-ALS_EY_REFL_PWR_MON_OUT H2:SUS-ETMY_M0_OFFSET_Y 10 5
PIT
./tdsdither 1.9 30 4 90 300 H2:SUS-ITMY_M0_TEST_P_EXC H2:ISC-ALS_EY_REFL_PWR_MON_OUT H2:SUS-ITMY_M0_OFFSET_P 10 5
./tdsdither 2.3 50 5 30 300 H2:SUS-ETMY_M0_TEST_P_EXC H2:ISC-ALS_EY_REFL_PWR_MON_OUT H2:SUS-ETMY_M0_OFFSET_P -10 5
The new tdsdither is a perl script replacement for the malfunctioning ezcademod which currently lives in userapps/trunk/isc/common/scripts. The attached image shows the power increase as the ITM and ETM alignment are dithered.
With the new channels names the commands are:
PIT
./tdsdither 1.9 30 4 90 300 H2:SUS-ITMY_M0_TEST_P_EXC H2:ALS-Y_REFL_B_PWR_OUT H2:SUS-ITMY_M0_OFFSET_P 10 5
./tdsdither 1.9 30 4 90 300 H2:SUS-ETMY_M0_TEST_P_EXC H2:ALS-Y_REFL_B_PWR_OUT H2:SUS-ETMY_M0_OFFSET_P -10 5
YAW
./tdsdither 1.9 30 4 90 300 H2:SUS-ITMY_M0_TEST_Y_EXC H2:ALS-Y_REFL_B_PWR_OUT H2:SUS-ITMY_M0_OFFSET_Y 10 5
./tdsdither 1.9 30 4 90 300 H2:SUS-ETMY_M0_TEST_Y_EXC H2:ALS-Y_REFL_B_PWR_OUT H2:SUS-ETMY_M0_OFFSET_Y 10 5