Displaying reports 85241-85260 of 88435.Go to page Start 4259 4260 4261 4262 4263 4264 4265 4266 4267 End
Reports until 06:44, Thursday 28 June 2012
H2 SUS
jeffrey.kissel@LIGO.ORG - posted 06:44, Thursday 28 June 2012 - last comment - 08:52, Thursday 28 June 2012(3287)
Starting measurements of H2 SUS ETMY
Just a heads up: while y'all are asleep, I'muna gunna take some active measurements of ETMY, and perhaps gather some quiescent spectra of the TOP stage of TMSY while those are running. I hope to be done in 2 hours, starting from 9:30a ET, 6:30a PT. I have reserved this amount of time on the CDS reserve systems MEDM as well. Please, don't hesitate to call if you need me (617 452 3605) to stop before hand -- otherwise, consider me to be done at 11:30 ET, or 8:30a PT.
Comments related to this report
jeffrey.kissel@LIGO.ORG - 08:51, Thursday 28 June 2012 (3288)
Notes for later:

Measurement conditions:
BSC6-HPI is ON (Position feedback loops only), WD ARMED
BSC6-ISI is ON (Damping loops only), WD ARMED
H2SUSETMY 
 - damping loops OFF, 
 - P&Y offsets have been removed (they were P 2804 [ct] and Y 14443 [ct])
 - Coil Drivers in State 1, COIL enabled (LP OFF, or "ACQ") (and "properly" compensated)
 - All WDs ARMED (Thresh OSEM DC = [-30e3:30e3] OSEM AC = [20e3], ACT AC [55555])

Driving through the damping filters 
 - inputs off, 
 - default legacy filters ON 
 - default legacy gains ON
     - [L, T, V, R, P, Y] = [-1, -5, -2, -0.3, -0.1, -0.1]

Open Loop TF is from DAMP_EXC through FMs 1 and 10, response is DAMP_IN1, so OLG TF is in the same units of Sensor [ct]/ Sensor [ct], so it accurately represents the open loop gain.
Plant TF is uncalibrated, but the only calibration necessary is the usual scale factor of 60, so we can treat it as calibrated * 60.


Reference data from 2012-04-14 data set

Drive amplitudes (Started with standard out-of-loop, from TEST_EXC, TF templates):
[[ Watched for / confirm no ]] DAC saturations
L = 1000 [ct] (was 4500 [ct]); AC RMS = [F2, F3] = [4.4e3, 4.4e3]
P = 200 [ct] (was 200 [ct]); ACT AC RMS during meas: [F1, F2, F3] = [3e3, 1.6e3, 1.6e3]
Y = 300 [ct] (was 300 [ct]); ACT AC RMS during meas: [F2, F3] = [1.5e3, 1.5e3]

Data saved to .xmls:
SusSVN = /ligo/svncommon/SusSVN/sus/trunk/
${SusSVN}/QUAD/H2/ETMY/SAGM0/Data/
2012-06-28_1358_H2SUSETMY_M0_Mono_L_WhiteNoise_OLGTF.xml
2012-06-28_1358_H2SUSETMY_M0_Mono_P_WhiteNoise_OLGTF.xml
2012-06-28_1358_H2SUSETMY_M0_Mono_Y_WhiteNoise_OLGTF.xml
jeffrey.kissel@LIGO.ORG - 08:52, Thursday 28 June 2012 (3289)
I've finished these measurements. Stay tuned for data and analysis!!
H2 ISC
keita.kawabe@LIGO.ORG - posted 19:26, Wednesday 27 June 2012 - last comment - 22:03, Wednesday 27 June 2012(3284)
First aLIGO arm lock (Max, Jax, Elli, Daniel, Keita)

It's a shoddy lock, it only lasts for maybe 0.5 sec or so and unlocks, and after 0.5 sec or so it locks again, and this lock/unlock cycle is perfectly in sync with the alignment fluctuation, but it locks nevertheless!

The alignment is not that great, but when it locks we can see a very weak 00-mode spot on the ETM surface at the center of the mirror. Right before it unlocks, the spot shifts in PIT (so my assessment about YAW being a problem might have been wrong).

The real breakthrough was to lock the PLL. You would think that the PLL doesn't matter that much if you lock the laser to the arm, but in reality the frequency noise of Prometheus is so big that it masks things badly. Higher order mode peaks were there but indistinguishable from each other and the demod signal looked like a hopeless random noise hell masking the peaks. As soon as the Beckhoff model was fixed (I don't know why it broke in the first place) and we locked the PLL, we were able to see multiple resonances clearly.

After Jax and Elli somewhat refined the alignment, we turned the PDH lock loop on, and with some tweaking in the gain and sign I was able to find the beam spot on the ETM.

The DC level of the reflected light on the PDH PD is still fluctuating by a large amount, and we confirmed that the fluctuation is NOT from the clipping on the diode by using a power meter in front of the diode. It's not clear where the clipping is happening, it might be the Faraday, or upstream. I'll measure the power fluctuation in the Hartman sensor path tomorrow.

This is good enough of a victory for today.

Comments related to this report
keita.kawabe@LIGO.ORG - 22:03, Wednesday 27 June 2012 (3285)

I forgot to stop an injection that is going into one of the ETMY TEST filters.

If SUS/SEI people want to do some test, please don't forget to stop that.

H1 SEI
corey.gray@LIGO.ORG - posted 18:57, Wednesday 27 June 2012 - last comment - 10:28, Thursday 28 June 2012(3269)
HAM3 Dial Indicators & In-Vac Cabling (a first start)

(corey, jim)

Dial Indicator Install (this work was on Tues)

Dial Indicators used to monitor the HAM3 ISI/HEPI system are roughly in place.  This hardware should not be touched/bumped as it will be used to monitor and ultimately help position the HAM3 ISI. 

Cabling (this work started Wed)

In-Vac Cabling for HAM3ISI is mapped out according to D1002874.  Since Septum work finished up this afternoon, I started running Corner-1 cables to their feed through.  I was able to get all cables to the feedthrough (but opting NOT to screw down to feed-thru), EXCEPT for the H1 Actuator (it's 70" long cable was a foot or so too short!).  At any rate, I only ran cables for Corner-1.  I went to the other side of the chamber and separated Corner-3 cables from Corner-2 (since they're going to opposite sides of the Chamber).  Corner-3 looks like it will be the tough one to work on (due to feed-thru in middle of Chamber).

I labeled the dirty side of feedthroughs.

Images attached to this report
Comments related to this report
hugo.paris@LIGO.ORG - 10:28, Thursday 28 June 2012 (3291)

H1 Actuator cable will be replaced with a 135" (shortest available now)

LHO General
patrick.thomas@LIGO.ORG - posted 17:03, Wednesday 27 June 2012 (3283)
dust monitor moved
The dust monitor at location 15 in the LVEA was moved into the clean room over HAM 3 at around noon today. It is labeled 'R'. It seems to occasionally lose communication for a cycle or so. I'm not sure of the cause of this.
X1 SEI
hugo.paris@LIGO.ORG - posted 16:42, Wednesday 27 June 2012 (3282)
HAM-IS Unit #6 - Top Masses Moved

Greg, Jim, Hugo,

One could hear/feel both of the top mases resonate when being hit. We moved both masses and set them on a different set of washers (we used the same kind of washer as for the previous units). We adjusted the masses/wahsers position util we could not hear/feel the masses resonate anymore.

TF are running overnight. Hopefully, the unwanted resonances that were recorded in HF are now gone.

X1 SEI
corey.gray@LIGO.ORG - posted 15:58, Wednesday 27 June 2012 (3278)
HAMISI#7

(corey, greg, jim)

Spring Pull Down Assys were removed

Actuators were installed; serial numbers noted here.

Payload was put on the Stage-1

Also started some cabling.

(On HAMISI#6, we helped Hugo, as needed)

H2 SUS
jeffrey.kissel@LIGO.ORG - posted 14:30, Wednesday 27 June 2012 - last comment - 14:46, Wednesday 27 June 2012(3279)
H2 SUS I/ETMY TOP Stage Motion Plots
M. Evans, P. Fritschel, J. Kissel ... I think even R. Weiss (call it the B Team)

In order to make some more quantitative statements about how much the test masses are moving, given that The A Team suggests that the test masses are "wobbling too much at about 1Hz," preventing cavity flashes, the B Team took some spectra of the top stage of each of the QUADs. Attached at the results.

There was some discussion that the excess motion was primarily in YAW, but the attached measurements (taken at 2012-06-27 2:00 UTC, which is late at night at LHO when no one was working) show that the most motion is in Pitch. That being said, there are times when Yaw is the larger motion -- we took an ETMY spectra (which we didn't capture because we were so freaked out by it) that we believed to be over today's local lunch time, and saw much more yaw, with resonances at almost exactly 0.4, 0.5, 0.6, and 0.7 Hz. We figured it was some sort of excitation; either an active measurement or outside-of-chamber excitations.

The RMS Pitch motion for both test masses at this time is roughly 0.5-0.7 microradians at 2012-06-27 2:00 UTC.

Remember, this is a measure of the motion at the TOP mass, and NOT a direct measure of test mass motion...

We can't yet make any further statements about the *source* of this excess motion (i.e. why is Pitch so much larger than Yaw). Stay tuned.

Details
-------
The xmls (of the same name) can be found here:
SusSVN = /ligo/svncommon/SusSVN/sus/trunk/;
${SusSVN}/QUAD/H2/?TMY/SAGM0/Data/

The calibration used for each of the channels is the same (thanks to dividing the rotation degrees of freedom by the lever arm, which is encoded into the OSEM2EUL matrix):

calibration = 1 / (BOSEM sensitivity [A/m] * SatAmp Transimpedance [V/A] * ADC calibration [ct/V])
            = 1 / (65e-3 [A/m] * 240e3 [V/A] * 2^16/40 [ct/V]) 
            = 3.9e-8 [m/ct]
Non-image files attached to this report
Comments related to this report
keita.kawabe@LIGO.ORG - 14:46, Wednesday 27 June 2012 (3280)

Huge YAW motion just before lunch today should be due to the excitation made for HWS commissioning.

X1 SEI
hugo.paris@LIGO.ORG - posted 11:32, Wednesday 27 June 2012 (3277)
HAM-ISI GS13 - Pod #68 cleaned and tested OK

Greg, Hugo

HAM-ISI horizontal GS13 Pod #68 was shiped to us dirty. It was opened here at LHO so the Pod could be cleaned. Once the pod was cleaned, the instrument was set back in the pod and tested this morning. HAM-ISI horizontal GS13 Pod #68 is still functional (Huddle test attached).

Next step, leak checking.

Non-image files attached to this report
H1 FMP
jodi.fauver@LIGO.ORG - posted 07:32, Wednesday 27 June 2012 (3274)
Xend Prep
Preparation of Xend for install work continued yesterday. The retrofit of the iLIGO cleanroom was completed. Gerardo check on the remaining OpLev Pylon near BSC9. 
H1 INS
jodi.fauver@LIGO.ORG - posted 07:16, Wednesday 27 June 2012 - last comment - 08:20, Wednesday 27 June 2012(3273)
Prep for HAM6 bellows install
John, Hugh, Bubba and I agreed on path toward installation of the SEI support tubes, bellows and table. Please see list below. 

1. Remove septum at HAM3/Inspect for identified leak/-Apollo-Cleanroom in place/Kyle worked on this yesterday
2. Test septum at HAM5/6-Kyle-Cleanroom in place
3. Move ion pump from HAM5 to HAM6-Kyle-Cleanroom in place/Kyle worked on this yesterday
4. Install all possible feedthroughs on BSC1/2/3 and HAM4/5/6; blank off as needed-Apollo-Appropriate purge needed/Hugh is working on this	
5. Install support tubes, support table and bellows per E980268 at HAM6-SEI/Apollo-Cleanroom in place
6. Pump down and leak check volume-Kyle/Gerardo/John-No cleanroom needed
Comments related to this report
john.worden@LIGO.ORG - 08:20, Wednesday 27 June 2012 (3275)

We plan to leak check between step 4 and 5 in order to avoid any ambiguity when testing the support tube bellows. So there will be two pump down/leak test cycles.

If leaks are found there may be additional pump/test cycles.

H2 ISC
keita.kawabe@LIGO.ORG - posted 22:34, Tuesday 26 June 2012 (3272)
Starting over (Jax, Elli, Max, Keita)

Summary:

The beam was likely very close to the right edge of ETMY since Friday, and this was due to the fact that we were only using TMS angle for the input beam pointing. We fixed this problem by using QPD servo and started over from scratch.

Now we're back to the point where we see some interference, and the good news is that the demod signal is much bigger than before (1V pp). Also we're seeing some change in the reflected DC power due to interference, unlike yesterday.

We still seem to be getting ultra higher order modes all over the place, and we don't see anything on the camera, so we need to refine alignment tomorrow.

The ETM and ITM are wobbling too much at about 1Hz, though. Due to this, the reflected beam seems to be clipped by either the Faraday aperture or the PDH diode aperture, and as a result the DC level of the PDH diode is changing by 30 to 50% constantly. This is not an interference effect (it changes even if you misalign ITM).

Also today the CM board A was not working at all. No output, fast and slow, regardless of the Beckhoff setting.

Alignment details:

When we started playing around with the alignment today, the demod output was the biggest when some light blob was hitting the right cage  bar of ETMY.  We tried many things but we always got back to this position. The likely cause of this is the fact that we only used TMS for initial pointing.

Since we initially only used the TMS angle to point the injection to the center of ITMY without using the PZTs on the ALS table, and since we needed to rotate the TMS so much, actually the ALS beam was falling off of one of the green QPDs. This means that there was a very high chance that the beam is not going through the center of the TMS primary.

Elli and I finished the QPD servo (a servo that uses PZT-driven steering mirrors so the beam from the ALS table is centered on two in-vac QPDs on the TMS) quickly so we didn't have to worry about QPDs. See Elli's alog entry.

After this, of course the pointing of TMS changed, so we started over by first aligning the TMS (with QPD servo on) to the center of the ITMY using baffle diodes, then aligning ITMY to the center of the ETMY using cage bars, then aligning ETMY to center the second beam on ITMY using baffle diodes.

Now we're getting much larger demod signal than before, and we can see that something is going on in the DC level (that is different from the clipping). And we don't see any light blob on the cage bars, so we know that the thing is not close to the edge any more. That's as far as we got today.

H1 PSL
michael.rodruck@LIGO.ORG - posted 18:07, Tuesday 26 June 2012 (3271)
PSL in low power mode

PSL is currently in low power mode, with the HPO off and only the frontend running. After tweaking alignment into the PMC the transmitted power is about 10W. PMC, ISS, and FSS are locked. If IO needs high power we will turn the HPO back on, but for now we will run with the frontend only.

IO has installed their own power control stage if they need less than 10W.

DBB plots are attached, taken after transition. For the 35W beam.

Non-image files attached to this report
H2 SEI
hugh.radkins@LIGO.ORG - posted 16:17, Tuesday 26 June 2012 (3270)
BSC7 SE Corner HEPI Actuators Removed re WP 3302
EricA & HughR
We managed 1 corner before our crane moving window closed.  7 to go (BSC7 & 4)
X1 SEI
corey.gray@LIGO.ORG - posted 16:06, Monday 25 June 2012 - last comment - 13:18, Wednesday 27 June 2012(3258)
HAMISI#7 Work and Serial Numbers

(corey, greg, jim)

HAM7ISI Springs have been installed, pulled-down, and Spring Safety hardware is in place.  Did a first run through on the Optics Table to pull out any broken/loose tangs.  The Optics Table can be installed tomorrow.  At this point, I was able to note quite a few serial numbers (s/n) while they were easily viewable.  Here are some of them:

Springs

(where the Tip is associated with each Corner;  i.e. a Spring which is bolted down to a Spring Post of Corner-3 actually has its Tip in the Corner-1 area)

Spring Posts

Flexures

Stage0:  014

Stage1:  010

Optics Table:  009

Comments related to this report
corey.gray@LIGO.ORG - 13:18, Wednesday 27 June 2012 (3276)

More Serial Numbers:

Actuators (installed 6/27)

  • H1:  179
  • V1:  097
  • H2:  178
  • V2:  118
  • H3:  176
  • V3:  007

CPS Probes (as slotted in satelite boxes)

  • H1:  12009
  • V1:  12025
  • H2:  12012
  • V2:  12016
  • H3:  12036
  • V3:  12030
X1 SUS
stuart.aston@LIGO.ORG - posted 19:33, Sunday 10 June 2012 - last comment - 16:19, Wednesday 27 June 2012(3056)
AOSEM responsivity measurements
[Stuart A, Mark B, Jeff B, Vern S]

Whilst last visiting LHO I was able to quickly make some open-light and one dimensional responsivity measurements using three dirty AOSEMs and a test-jig kindly loaned from Mark. The test-jig has previously been used for characterising BOSEMs, and so had to be reconfigured to accommodate the smaller AOSEM coilformer. More importantly, rather than using the rectangular flag employed for the BOSEM, a ~1" long x ~2 mm diameter cylindrical flag was provided by Jeff B.

A UK production Satellite Box (D0901284) was connected up to the AOSEM under test using a dirty in-vacuum quadrapuss harness (D1000234). The Satellite Box was provided with it's required supply lines via a Satellite Box Testing Board (courtesy of Filiberto). For electronics set-up please see image 504 below. A DVM was used to read-out the amplified voltage signal via the diagnostics port (J4) on the Satellite Box (Pins 9 and 28). Note that, the production Satellite Boxes have a input gain of 242k V/A or 0.242 µA/V (double-ended).

Image 506 (below) shows the opto-mechanical set-up for the reconfigured test-jig, including the translation stages and flag assembly. For these tests, only the responsivity is sought, and therefore a one-dimensional characterisation along the sensitive axis is adequate.

When connected up to the Satellite Box, each of the AOSEMs had the following open-light differential voltage measurements:-

- Unit #1, open-light = 14.75 V (i.e. an open-light photo-current of ~61 µA). Corresponds to ~24k counts
- Unit #2, open-light = 10.14 V (i.e. an open-light photo-current of ~42 µA). Corresponds to ~17k counts
- Unit #3, open-light = 12.19 V (i.e. an open-light photo-current of ~50 µA). Corresponds to ~20k counts

Over a ~0.7 mm operating range, these AOSEMs were found to have the following responsivity (see plot below):-

- Unit #1, responsivity = 18784 V/m (i.e. 78 mA/m).
- Unit #2, responsivity = 13028 V/m (i.e. 54 mA/m).
- Unit #3, responsivity = 15721 V/m (i.e. 65 mA/m).

These responsivity results can be compared with the default value we have previously assumed of ~80 mA/m (see LLO aLog entry 2715).

To summarise, these measurements can be used to validate our assumption of using the AOSEM calibration factor of, 1/(80e-3 [A/m] * 240e3 [V/A] * (2^16)/40 [cts/V]) = 3.2e-8 [ct/m], is consistent for units with open-light counts above Jeff K's goal of 25k.
Images attached to this report
Non-image files attached to this report
Comments related to this report
stuart.aston@LIGO.ORG - 07:58, Wednesday 13 June 2012 (3109)
Please find the responsivity plot showing all three units tested below.
Non-image files attached to this comment
mark.barton@LIGO.ORG - 16:19, Wednesday 27 June 2012 (3281)
Mark Barton and Szymon Steplewski

The responsivities of the three units test by Stuart have a scatter of about 18% (stdev//mean). However this scatter is dominated by a term proportional to the open light voltage (or counts). If you scale the responsivity to an effective OL count of 30000, as is routinely set in the OSEMINF block, the scatter is much reduced (to 0.6%). Therefore the number that it is useful to quote is the average of the scaled responsivities. See attached spreadsheet.

However although this data set is useful for making the above point, it was still taken with the wrong flag (2.5 mm instead of 2 mm) and so should not be considered final.
Non-image files attached to this comment
Displaying reports 85241-85260 of 88435.Go to page Start 4259 4260 4261 4262 4263 4264 4265 4266 4267 End