LHO Assembly#3 Stage0 Base Level Check
Before moving the Stage1 PreAssembly onto the Stage0 Base on Tuesday, we checked the Base top surface bolted to the Test Stand for level.

Attached is my logbook copy of the observations.
Bottom line: Of 22 observations, a total range of 7.5mils.  Discard 1 reading nowhere near a support post and 21 observation are +-2.5mils.  
Non-image files attached to this report
H2 DAQ
david.barker@LIGO.ORG - posted 18:50, Thursday 19 August 2010 (145)
H2 DAQ build starting
We (Rolf, Alex, Dave, Richard) started building the H2 aLIGO DAQ system
this week. Since it is being constructed and tested on the DTS,
this week's alogs will be filed under the DTS section but in part cover
the H2 DAQ system.
X1 DTS
david.barker@LIGO.ORG - posted 18:44, Thursday 19 August 2010 (144)
Rolf and Alex visit to test H2 DAQ using DTS
Rolf and Alex's visit started yesterday, August 18th. 
This visit will extend through to next Wednesday 25th.

Just a quick alog to note the start. The DAQ test stand
is being reconfigured as a H2 simulation to load test
the new H2 DAQ system. 

The H2 DAQ rack was moved from the MSR into the DTS room,
and the h2daqdc0 and h2daqnds0 were built for the
initial testing.

More detailed alogs with pictures to follow. As-built drawings
will be posted to the DCC.
X1 SUS
david.barker@LIGO.ORG - posted 18:24, Thursday 19 August 2010 (143)
Reconfigured DAQ, added channels, turned on second trends
Dave and Alex,

Using Mark's full list of 64 fast channels which should be acquired
by the DAQ we increased L1QTS.ini from 25 chans to the required 64 chans.

All fast channels are being acquired at 2048Hz.

We attempted to turn on the second and minute trends, but found that starting
minute trends crashed the DAQ. Alex took a look at the code, but was unable
to find the cause. So for now, we are only acquiring full frame and second 
trends. 

I did the math, and figured that with the disk space available we can have:

14 days of second trends
11.5 days of full data

We can extend the second trend look back at the expense of full frames
if this is required. 

The DAQ was restarted many times between 17:30 and 18:30 for this work.
X1 SEI
jeffrey.garcia@LIGO.ORG - posted 15:35, Thursday 19 August 2010 (142)
LHO X1 unit_2 H1&V2 cables swapped with H2&V2
Hugh R., Eric A., Jeff G.

We believe we have found the solution to the odd GS-13 behavior from the transfer function measurements.  After several failed attempts to implement the damping loops, the path from each GS-13 to the feedthrough board was traced to see if any cables had been swapped since unit_1 testing. 

 Hugh and Eric noticed the "clean side" of the feedthrough for H1&V1 had been swapped with H2&V2. Since both GS-13s for each location (i.e. 1 & 2) are on the same cable up to the feedthrough, H1 & V1 were being mistaken for H2 & V2 and vice versa.  After the swap, a quick test from 200-800Hz showed the Horizontals and Verticals were fairly close in magnitude in this bandwidth, similar to unit_1.  Full measurements of the full bandwidth to be posted soon.

Shortly thereafter, the damping loops were implemented successfully with gains of -1.  I will set up long collocated and coordinate Transfer Function measurements for tonight.
H2 General
betsy.weaver@LIGO.ORG - posted 14:56, Thursday 19 August 2010 (141)
LHO Q1 damping
We discovered that turning the damping off at the output of the DOF filter bank doesn't give the QUAD a kick (because it is more appropriately placed wrt the integrator).  So, to damp, you turn the input and output switches on, but to turn damping off, you must turn the output switches off first.  Then before running the TF, you turn the input switches off, then the output switches back on.  Coherence looks MUCH improved after a shot of damping in this manor.

A 2k signal swing on pitch appears to be as quiet as it gets (without damping).

Had to restart the DAQ (again) today.  
H2 General
james.batch@LIGO.ORG - posted 07:58, Thursday 19 August 2010 - last comment - 10:08, Thursday 19 August 2010(139)
Added workstation to SEI test stand
Modified seiteststand computer to export /cvs, /apps, and /home/controls, restarted nfs.  Changed /etc/hosts entry for 10.11.0.94 to workstation.

Set workstation IP to 10.11.0.94, disabled DHCP, nfs mounted /opt, /apps, /cvs, and /home/controls from seiteststand.  Removed /home/controls/*, ~controls is now nfs mounted from seiteststand.  Added shared library config files to /etc/ld.so.conf.d/, recached shared libraries.  

Note that ssh is still directed to seiteststand, but controls can ssh to workstation for non-front end work.  The user "controls" can log in on the workstation and should have the same environment as on the workstation.  Did not do exhaustive testing, so there may be some more work to do on workstation.
Comments related to this report
james.batch@LIGO.ORG - 10:08, Thursday 19 August 2010 (140)
Added NDSSERVER environment variable with value 10.11.0.24:8088 to .bashrc and .cshrc, should cause initial value of NDS server fields in GDS gui applications to show 10.11.0.24, port 8088.
H2 General
betsy.weaver@LIGO.ORG - posted 14:41, Wednesday 18 August 2010 (138)
LHO Q1 testing
Yesterday, Mark did some tuning of the DOF loop gains.  They now do some damping with the "simple" filter engaged, but more loop tuning is needed.  There signals see a huge kick when the damping is turned off.  This needs investigation.

I'm rebooting the DAQ since DTT is now giving "Test Timed-out" again (done once yesterday as well).
X1 SEI
corey.gray@LIGO.ORG - posted 14:06, Wednesday 18 August 2010 (137)
Unit#2 Longer & Cleaner M2M Plant Measurements
Last night I ran one of the long(~15hr) M2M Plant measurements [vs the 4hr one I ran yesterday].  Overall, there's nothing new with the results--main issue, once again, is the 180deg out of "phaseness" for the Y & RY GS13.

From the 4hr Measurements of yesterday, this is the input I've heard back thus far:

L2L (H1H2 & V1V2 plant magnitudes look bad):
--Possible saturations (Rich M. didn't think so, but Kissel & Rich said we should have a "saturation check" built into our measurement)
--Problem with the Interface Chasis (seems like since we have issues with h1v1 & h2v2, we would have issues with 2 of our 3 chasis)

M2M (180deg phase diff for Y & RY):
--Possible sign issue with the matrices

From an email from Fabrice, it sounds like once we resolve this issue with the GS13's, we should then try to run DAMPING on the system---it should work.

As for this measurement, nothing new is learned, other than we know we can run some really long matlab measurements over a work night with no problem.
Non-image files attached to this report
X1 SEI
hugh.radkins@LIGO.ORG - posted 09:42, Wednesday 18 August 2010 (136)
LHO Assembly #3 Stage1 SubAssembly to Stage0 Base Assembly
Attached the Stage1 Floor Pre-Assembly to the Stage0 Assembly on the Test Stand for LHO Assembly #3.  No issues in this move.
Attached are a couple photos near completion.  JimW EricA MitchR

PS First Image is not related directly to this log but it won't delete--H
Images attached to this report
X1 SEI
corey.gray@LIGO.ORG - posted 17:35, Tuesday 17 August 2010 (135)
Unit#2 Cartesian Undamped Plant (Transfer Function) Via Matlab
Ran the Modal to Modal (i.e. Cartesian) plan measurement.  This measurement was run WITHOUT DAMPING, and most of it took place while activity was minimal (i.e. quiet).

Results Comments (comparing to the Unit#1 Document)
[pdf plots attached]
Horizontal GS13s:
The magnitude of the plant looks fairly identical to the Unit#1.  The oddity here is the phase of Y ::: What's up with it being 180deg out of phase??

Horizontal CPSs:
Looks fairly similar to Unit#1.

Vertical GS13's:
Similar to the horizontal, the magnitude of the plant, but here we have the RY off in phase by 180deg.

Vertical CPS's:
Looks fairly similar to Unit#1.

****Below are the locations of the measurement files (they've been svn-added & committed)***

All files are at [seiteststand svn]: /opt/svncommon/seisvn/seismic/HAM-ISI/X1/

MEASUREMENT FILE LOCATION: [seiteststand svn]/Scripts/DataCollection/unit_2/
FILE NAMES:
TFcollect_100817_M2M_0p05to5Hz.m
TFcollect_100817_M2M_5to200p5Hz.m
TFcollect_100817_M2M_200to800Hz.m

DATA FILE LOCATION: [seiteststand svn]/Data/unit_2/TransferFunctionData/
FILE NAMES:
TFcollect_100817_M2M_0p05to5Hz_test1.mat
TFcollect_100817_M2M_5to200p5Hz_test1.mat
TFcollect_100817_M2M_200to800Hz_test1.mat


PLOTTING/DATA-CONCACENATING FILE LOCATION: [seiteststand svn]/Scripts/DataAnalysis/unit_2/
FILE NAME:
TFanalyze_100817_M2M.m

.pdf & .fig FILE LOCATION: [seiteststand svn]/Data/unit_2/Figures 
Non-image files attached to this report
X1 SEI
corey.gray@LIGO.ORG - posted 13:39, Tuesday 17 August 2010 - last comment - 14:19, Tuesday 17 August 2010(132)
Unit#2 Collocated Undamped Plant (Transfer Function) Via Matlab
This is the first set of Matlab transfer functions run on Unit#2.  This was run via Fabrice's measurement files made for Unit#1.  This is a collocated measurement (i.e. H1 to H1, H2 to H2...V1 to V1, etc. versus X to X, ...RX to RX, etc.).  This measurement was run WITHOUT DAMPING.  

Something Amiss
At a first glance, something looks wrong with the GS13's.  H3 & V3 look noticeably different from H1H2 & V1V2.  But as Hugh noticed, when you look at the same measurement for Unit#1 (seen in this document), the H3 & V3 plants on Unit#2 look like all the plants on Unit#1.  So not really sure what's the issue here.  

The Capacitive Position Sensors look fine at a first glance.Will continue making more plant (transfer function) measurements and keep an eye on the GS13's.

Have attached pdfs of the plants to this elog.(sorry, they're in portrait...I don't know how to print things in landscape on matlab).


****Below are the locations of the measurement files (they've been svn-added & committed)***


All files are at [seiteststand svn]:  /opt/svncommon/seisvn/seismic/HAM-ISI/X1/

MEASUREMENT FILE LOCATION:  [seiteststand svn]/Scripts/DataCollection/unit_2/
FILE NAMES:
TFcollect_100816_L2L_0p05to0p5Hz.m
TFcollect_100816_L2L_0p05to5Hz.m
TFcollect_100816_L2L_5to200p5Hz.m
TFcollect_100816_L2L_200to800Hz.m

DATA FILE LOCATION:  [seiteststand svn]/Data/unit_2/TransferFunctionData/
FILE NAMES:
TFcollect_100816_L2L_0p05to0p5Hz_test1mat.mat
TFcollect_100816_L2L_0p05to5Hz_test1.mat
TFcollect_100816_L2L_5to200p5Hz_test1.mat
TFcollect_100816_L2L_200to800Hz_test1.mat


PLOTTING/DATA-CONCACENATING FILE LOCATION:  [seiteststand svn]/Scripts/DataAnalysis/unit_2/
FILE NAME:
TFanalyze_100816_L2L.m

.pdf & .fig FILE LOCATION:  [seiteststand svn]/Data/unit_2/Figures
Non-image files attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 13:43, Tuesday 17 August 2010 (133)
It should be mentioned that the 200-800Hz part of this measurement was run last night (Monday 8/16).  The 5-200Hz, 0.5-5Hz, and 0.05-0.5Hz measurements were run today (Tuesday) during the day when there was noisy assembly work going on at Unit#3 (but the Watchdog never tripped for these measurements).
fabrice.matichard@LIGO.ORG - 14:19, Tuesday 17 August 2010 (134)
There is definitely something wrong on H1,H2,V1,V2 seismometers. Don't they share the same interface chassis? Can we check if everything is ok with the chassis (power supply, current limit...)

This explains why the damping loop was unstable; on the attached document:

- First  page, I follow up on Corey's filter measurement from yesterday. I compare it to the design. It matches. No problem here.

- On the second page, I plot the open loop using the measurements Corey has just posted. It cross over at 1.4Hz with negative phase margin. 

Everything should work once we find out what is wrong with these 4 GS13s. 




Non-image files attached to this comment
X1 SUS
betsy.weaver@LIGO.ORG - posted 12:30, Monday 16 August 2010 - last comment - 09:07, Tuesday 17 August 2010(130)
LHO Q1 Testing
This morning, Mark rearranged some +/- signs of gains here and there in an attempt to calibrate the output of Mo signals to motion of magnet repels/attractions.  Originally, we set all settings as per Brett's LASTI medms (E10000078), however this meant that the OSEM naming conventions were set as you viewed each chain face on.  Mark's changes are such that the QUAD is viewed entirely from the reaction side (similar to iLIGO) which makes driving it from an operations stand point a bit easier.  The Ro settings are the same as called out in the LASTI test plan.  On the Mo chain settings needed adjusting to do this. 

Damping appears to be working, but now DTT keeps giving a test timed-out error.  Calling Dave...


Comments related to this report
betsy.weaver@LIGO.ORG - 09:07, Tuesday 17 August 2010 (131)
Just after this, we also discovered that the MO RIGHT BOSEM started misbehaving after we shrouded the QUAD with foil in an attempt to slow air current motion.  The channel became very glitchy, even when disconnected from the BOSEM.  We tracked this down to the 25pin-25-pin gold cable - Richard is going to help us investigate this.  In the interim, we may switch the cable with the one from R0 so that we can keep moving on M0 measurements.
X1 SEI
corey.gray@LIGO.ORG - posted 11:11, Monday 16 August 2010 - last comment - 12:26, Monday 16 August 2010(128)
gx01 & gisiham Killed & Restarted
Last week, the Test Stand crashed (that's twice since we've been in the Staging Building...not counting the recent power outage).

This morning I
* Opened terminal, ssh-ed into frontend(stormy), ran the "killg1isiham" & then the "killg1x01" scripts
* Opened terminal, ssh-ed into frontend(stormy), typed "sudo reboot"
* Opened terminal, ssh-ed into frontend(stormy), ran "startg1x01" & then "startg1isiham"

Everything appears to look alright, although the Overflow counters on the GDS_TP_Custom screens are counting (but maybe they always do this...due to unconnected L4C's).
Comments related to this report
corey.gray@LIGO.ORG - 12:26, Monday 16 August 2010 (129)
Even after this reboot of the Test Stand, several applications are running slow.  
X1 SEI
corey.gray@LIGO.ORG - posted 14:49, Wednesday 11 August 2010 (127)
Calibrated GS13 Spectra from Unit#2
Here is the calibrated GS13 Spectra from Unit #2 (note:  These are the "reused" GS13's---they'll be reused from Unit to Unit until we start receiving GS13's which we can keep with a unit.  So these same GS13's were used in Unit#1).  With Jeff Kissel's help, I calibrated the data via DTT.  Here is the DTT Calibration info for the GS13's and the GS13 Interface Board:  

(this is all for the frequencies we look at ~100Hz)

Units:  m/s
Gain:  3.5e-9
Poles:  0,0,50
Zeros:  0.1 1, 10

The plots are for when the Table is locked & unlocked.


Non-image files attached to this report