Reports until 08:00, Monday 21 August 2023
LHO General
austin.jennings@LIGO.ORG - posted 08:00, Monday 21 August 2023 (72348)
Ops Day Shift Start

TITLE: 08/21 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 151Mpc
OUTGOING OPERATOR: Corey
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 3mph Gusts, 2mph 5min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.18 μm/s 
QUICK SUMMARY:

- H1 locked for 15.5 hours

- SEI/CDS ok

LHO General
ryan.short@LIGO.ORG - posted 00:00, Monday 21 August 2023 (72346)
Ops Eve Shift Summary

TITLE: 08/20 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 151Mpc
INCOMING OPERATOR: Corey
SHIFT SUMMARY: Quiet shift; recovered from last shift's EQ lockloss and kept observing throughout. H1 has now been locked for 7.5 hours.

LOG:

No log for this shift.

LHO General
ryan.short@LIGO.ORG - posted 20:00, Sunday 20 August 2023 (72347)
Ops Eve Mid Shift Report

State of H1: Observing at 153Mpc

H1 was able to relock automatically following the lockloss from the last shift and has now been observing for 3.5 hours.

LHO General
ryan.short@LIGO.ORG - posted 16:02, Sunday 20 August 2023 (72345)
Ops Eve Shift Start

TITLE: 08/20 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
OUTGOING OPERATOR: Austin
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 6mph Gusts, 4mph 5min avg
    Primary useism: 0.03 μm/s
    Secondary useism: 0.19 μm/s
QUICK SUMMARY: H1 is relocking following an earthquake-caused lockloss, currently up to ENGAGE_ASC_FOR_FULL_IFO

LHO General
austin.jennings@LIGO.ORG - posted 16:00, Sunday 20 August 2023 (72341)
Sunday Operator Summary

TITLE: 08/20 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Lock Aquisition
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY:

- 20:19 - inc 5.7 EQ from South Sandwich Islands

- Superevent S230820bq - call received at 21:26 UTC, no alert on verbal

- 21:43 - inc 5.0 EQ from SoCal

- H1 did an auto initial alignment, just completed and now relocking as I leave the IFO to Ryan S.

LOG:

No log for this shift.

H1 General (Lockloss)
austin.jennings@LIGO.ORG - posted 14:50, Sunday 20 August 2023 (72344)
Lockloss @ 21:47

Lockloss @ 21:47, caused by local EQs.

LHO General
austin.jennings@LIGO.ORG - posted 13:21, Sunday 20 August 2023 (72343)
Mid Shift Report

H1 has been locked for 45 hours. Nothing to note locally, but we just got an alert for a 5.7 EQ from South Sandwich Islands region.

LHO VE
david.barker@LIGO.ORG - posted 10:16, Sunday 20 August 2023 (72342)
Sun CP1 Fill

Sun Aug 20 10:06:46 2023 INFO: Fill completed in 6min 42secs

Images attached to this report
LHO General
austin.jennings@LIGO.ORG - posted 08:00, Sunday 20 August 2023 (72340)
Ops Day Shift Start

TITLE: 08/20 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 149Mpc
OUTGOING OPERATOR: Corey
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 7mph Gusts, 4mph 5min avg
    Primary useism: 0.01 μm/s
    Secondary useism: 0.16 μm/s 
QUICK SUMMARY:

- H1 still going strong, right now at a 39:45 hour lock

- Systems stable, ground motion low

- Optics lab dust monitor alarm on alert handler - possibly wild fires?

LHO General
ryan.short@LIGO.ORG - posted 00:00, Sunday 20 August 2023 (72338)
Ops Eve Shift Summary

TITLE: 08/19 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 150Mpc
INCOMING OPERATOR: Corey
SHIFT SUMMARY:

H1 has now been locked for 32 hours. Very quiet evening with observation time throughout.

The EY VEA dust monitor alarm started up again shortly after mid-shift. Attached is a trend of the dust counts over the past 8 hours.

LOG:

No log for this shift.

Images attached to this report
LHO General
ryan.short@LIGO.ORG - posted 20:00, Saturday 19 August 2023 (72339)
Ops Eve Mid Shift Report

State of H1: Observing at 150Mpc

H1 has now been locked for 28 hours. Quiet evening on site; the EY VEA dust monitor alarm has stopped.

LHO General
ryan.short@LIGO.ORG - posted 16:10, Saturday 19 August 2023 (72337)
Ops Eve Shift Start

TITLE: 08/19 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 152Mpc
OUTGOING OPERATOR: Austin
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 17mph Gusts, 15mph 5min avg
    Primary useism: 0.05 μm/s
    Secondary useism: 0.16 μm/s
QUICK SUMMARY: H1 has now been locked for 24 hours.

LHO General
austin.jennings@LIGO.ORG - posted 16:00, Saturday 19 August 2023 (72334)
Saturday Operator Summary

TITLE: 08/19 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 152Mpc
INCOMING OPERATOR: Ryan S
SHIFT SUMMARY:

- EY DM 1 (H1:PEM-EY_DUST_VEA1_300NM_PCF) has been intermittently going off on alert handler - possibly due to wildfires, scope attatched

- Superevent S230819ax - call received at 17:21 UTC, no alert on verbal

- Overall a very quiet (and smoky) day, leaving the IFO to Ryan S. just under a 24 hour lock
LOG:

No log for this shift.

Images attached to this report
LHO General
austin.jennings@LIGO.ORG - posted 12:29, Saturday 19 August 2023 (72336)
Mid Shift Report

H1 still locked for 20 hours now. Systems appear stable, ground motion is still low.

LHO VE
david.barker@LIGO.ORG - posted 11:10, Saturday 19 August 2023 (72335)
Sat CP1 Fill

Sat Aug 19 10:08:43 2023 INFO: Fill completed in 8min 39secs

Images attached to this report
LHO General
austin.jennings@LIGO.ORG - posted 08:02, Saturday 19 August 2023 (72333)
Ops Day Shift Start

TITLE: 08/19 Day Shift: 15:00-23:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 153Mpc
OUTGOING OPERATOR: Corey
CURRENT ENVIRONMENT:
    SEI_ENV state: CALM
    Wind: 16mph Gusts, 12mph 5min avg
    Primary useism: 0.02 μm/s
    Secondary useism: 0.15 μm/s 
QUICK SUMMARY:

- H1 is still locked - going on 16 hours

- All systems stable, DMs read out ok, SEI motion low

LHO General (SQZ)
ryan.short@LIGO.ORG - posted 00:00, Saturday 19 August 2023 (72329)
Ops Eve Shift Summary

TITLE: 08/18 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 152Mpc
INCOMING OPERATOR: Corey
SHIFT SUMMARY: H1 has been at locked for almost 8 hours. Quiet shift after H1 locked except for one brief drop out of observing.

LOG:

No log for this shift.

LHO General
ryan.short@LIGO.ORG - posted 20:00, Friday 18 August 2023 (72332)
Ops Eve Mid Shift Report

State of H1: Observing at 153Mpc

H1 has been locked and observing for almost 4 hours. Range has increased to above 150Mpc in the past hour, possibly from the wind dying down?

Images attached to this report
H1 PEM (DetChar)
robert.schofield@LIGO.ORG - posted 19:22, Friday 18 August 2023 - last comment - 11:13, Monday 11 September 2023(72331)
DARM 52 Hz peak from chilled water pump at EX: HVAC shutdown times

Genevieve, Lance, Robert

To further understand the roughly 10Mpc lost to the HVAC (https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=72308), we made several focussed shutdowns today. These manipulations were made during observing (with times recorded) because such HVAC changes happen automatically during observing and also, we were reducing noise rather than increasing it. The times of these manipulations are given below.

One early outcome is that the peak at 52 Hz in DARM is produced by the chilled water pump at EX (see figure). We went out and looked to see if the vibration isolation was shorted, it was not, though there are design flaws (the water pipes arent isolated). We switched from CHWP-2 to CHWP-1 to see if the particular pump was extra noisy. CHWP-1 produced a similar peak in DARM at its own frequency. The peak in accelerometers is also similar in amplitude to the one from the water pump at EY. One possibility is that the coupling at EX is greater because of the undamped cryobaffle at EX.

 

Friday HVAC shutdowns; all times Aug. 18 UTC

15:26 CS SF1, 2, 3, 4 off

15:30:30 CS SF5 and 6 off

15:36 CS SF5 and 6 on

15:40 CS SF1, 2, 3, 4 back on

 

16:02 EY AH2 (only fan on) shut down

16:10 EY AH2 on

16:20 EY AH2 off

16:28 EY AH2 on

16:45 EY AH2 and chiller off

16:56:30 EY AH2 and chiller on

 

17:19:30 EX chiller only off, pump stays on

17:27 EXwater pump CHWP-2 goes off

17:32: EX CHWP-2 back on chiller back on right after

 

19:34:38 EX chiller off, CHWP-2 pump stays on for a while

19:45 EX chiller back on

 

20:20 EX started switch from chiller 2 to chiller 1 - slow going

21:00 EX Finally switched

21:03 EX Switched back to original, chiller 1 to chiller 2

 

Non-image files attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 10:29, Monday 21 August 2023 (72350)DetChar, FMP, ISC, OpsInfo
Turning Roberts reference to LHO:72308 into a hyperlink for ease of navigation.

Check out LHO:72297 for a bigger picture representation of how the 52 Hz peak in the broader DARM sensitivity, and from the Time Stamps in Elenna's plots, they were taken at 15:27 UTC, just after the corner station (CS) "SFs 1, 2, 3, 4" are off.

SF stands for "Supply Fans" i.e. those air handler unit (AHU) fans that push the cool air in to the LVEA. Recall, there are two fans per air handler unit, for the two air handler units (AHU1 and AHU2) that feed the LVEA in the corner station.

The channels that you can use to track the corner station's LVEA HVAC system are outlined more in LHO:70284, but in short, you can check the status of the supply fans via the channels
    H0:FMC-CS_LVA_AH_AIRFLOW_1   Supply Fan (SF) 1
    H0:FMC-CS_LVA_AH_AIRFLOW_2   Supply Fan (SF) 2
    H0:FMC-CS_LVA_AH_AIRFLOW_3   Supply Fan (SF) 3
    H0:FMC-CS_LVA_AH_AIRFLOW_4   Supply Fan (SF) 4
jeffrey.kissel@LIGO.ORG - 13:13, Monday 28 August 2023 (72486)DetChar, ISC, SYS
My Bad: -- Elenna's aLOG is showing the sensitivity on 2023-Aug-17, and the Robert logging of times listed above are for 2023-Aug-18. 

Elenna's demonstration is during Robert's site-wide HVAC shut down 2023-Aug-17 -- see LHO:72308 (i.e. not just the corner as I'd errantly claimed above.).
jeffrey.kissel@LIGO.ORG - 11:13, Monday 11 September 2023 (72805)FMP, ISC, OpsInfo
For these 2023-Aug-18 times mentioned in this LHO aLOG 72331, check out the subsequent analysis of impact in LHO:72778.
H1 PEM (DetChar)
robert.schofield@LIGO.ORG - posted 17:53, Thursday 17 August 2023 - last comment - 10:26, Monday 21 August 2023(72308)
PEM activites Wed. and Thurs.: PEM injections, bias sweep, HVAC shutdown breaks 160 Mpc (for a few minutes)

Lance, Genevieve, Robert

PEM injections

We are redoing part of the formal PEM injection program, which took place for a week before the run, because the 75-60W change reduced vibration coupling by factors of 2 or 3. On Wednesday, during the commissioning slot, we finished acoustic injections at EY and started shaker injections at EY. Thursday we finished the main shaker injections at EY.

ETMY bias sweep with electronic ground injections

Fig. 1 shows that the ETMY bias setting that minimizes our electronic ground injection coupling has possibly changed a little, but not much, since January.

HVAC shutdown

I shut down the HVAC, site-wide, from about 15:23 to 15:37 Aug 17 UTC. The range increased by a little less than 10 Mpc to a little over 160 Mpc. Elenna posted a spectrum for the best part of the site-wide shutdown (see below). The shutdown and especially the re-start took time, so Fig. 2 shows just the effect of of the chilled water system at EX. Also, we shut down SF4 only (the fan pushing 11,000 CFM at the CS, from 21:18 to 21:32 UTC, but we did not see an improvement in range. We will continue with a focussed study tommorrow in order to better understand the locations of the problems.

Non-image files attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 10:26, Monday 21 August 2023 (72349)DetChar, FMP, ISC
For the ASD of GDS-CALIB_STRAIN of Elenna's that Robert mentions comparing the HVAC ON vs. OFF times see LHO:72297.
Displaying reports 18461-18480 of 88690.Go to page Start 920 921 922 923 924 925 926 927 928 End