Reports until 11:08, Monday 14 December 2015
H1 CAL (CAL)
joseph.betzwieser@LIGO.ORG - posted 11:08, Monday 14 December 2015 - last comment - 14:34, Wednesday 30 December 2015(24204)
H1 calibration measurements and script clean up
We've been cleaning up the scripts used to present the various calibration measurements against the model and each other.

A longer description of script locations and cleanup is LLO alog 23558.

This is basically the same as  LHO alog 21280, except comparing against the O1 model (H1DARMparams_1124827626.m) and trying to use more generic scripts for both sites.

The attached pdfs are results, and can also be found in the aligo calibration svn under:
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O1/H1/Results/

The first 3 all measurement types (Free swinging Michelson, ALS DIFF, PCAL) from 3 different days plotted against each other and the O1 model.

The second set of 3 are just the PCAL measurements against the model.
Non-image files attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 14:34, Wednesday 30 December 2015 (24570)
The all-method comparison plots attached here have been renamed to 
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O1/H1/Results/
2015-12-11_H1SUSETMY_ActuationCoeffComp_EYL1_AllMethods.pdf
2015-12-11_H1SUSETMY_ActuationCoeffComp_EYL2_AllMethods.pdf
2015-12-11_H1SUSETMY_ActuationCoeffComp_EYL3_AllMethods.pdf
in order to distinguish them from the L1 results, and committed to the repo.

The PCAL-only results have been moved into the PCAL subdirectory and similarly renamed,
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O1/H1/Results/PCAL/
2015-12-11_H1SUSETMY_ActuationCoeffComp_PCAL_EYL1_Residuals.pdf
2015-12-11_H1SUSETMY_ActuationCoeffComp_PCAL_EYL2_Residuals.pdf
2015-12-11_H1SUSETMY_ActuationCoeffComp_PCAL_EYL3_Residuals.pdf