LHO O1 Uncertainty Budget at GPSTime = 1135136350
C. Cahillane

I have constructed the uncertainty budget of LHO at GPSTime = 1135136350.

The kappa values are given at 11546.

Just a reminder on the differences between the calibration versions (according to me and my results):

C00 = Sensing, Actuation, and Digital filters given by DARMmodel (I used the DARMparams from GPSTime = 1127083151)
C01 = No kappa corrections, but static frequency dependence corrected.
C02 = Kappa_tst and kappa_C corrected, as well as static frequency dependence corrected. Kappa_pu and cavity pole f_c NOT corrected.
C03 = "Perfect" calibration, i.e. all kappas and static frequency dependence corrected. 

All comparisons between calibration versions have the C03 "Perfect" calibration in the denominator.  C03 represents the best possible knowledge of the detector according to the calibration group.  All others have some known systematic errors. 

For C01, strain magnitude uncertainty is below 7% and strain phase uncertainty is below 3.5 degrees. (See PDF 1 Plot 2)
For C01, maximum strain magnitude error over C03 is 0.95 and maximum strain phase error over C03 is below 3 degrees. (See PDF 1 Plot 1)