Reports until 17:33, Monday 22 February 2016
H1 CAL (CAL)
craig.cahillane@LIGO.ORG - posted 17:33, Monday 22 February 2016 (25667)
LHO O1 Uncertainty Budget at GPSTime = 1126259461
C. Cahillane

I have removed a double-counting error found in the final total uncertainty budget.  All of the original fits for each component remain the same, but the final budget is reduced for each actuation stage and the sensing function by a little under a factor of sqrt(2).

I have posted the new results below for C01, C02, and C03.  You can run the updated code at the calibration SVN:
aligocalibration/trunk/Runs/O1/Common/MatlabTools/strainUncertainty_Final_O1.m

For the equivalent LLO Budget please see aLOG 24915.
Non-image files attached to this report