Displaying report 1-1 of 1.
Reports until 18:42, Sunday 21 January 2024
H1 SUS (SUS)
rahul.kumar@LIGO.ORG - posted 18:42, Sunday 21 January 2024 - last comment - 18:52, Sunday 21 January 2024(75492)
In air transfer function measurements of suspensions in HAM7 - for the upcoming in-chamber work

Attached below are the snapshots of the transfer function measurements I took yesterday before we kick start the in-chamber work next week. The suspensions look healthy and is currently in air.

The templates are stored at the following location,

OPO

/ligo/svncommon/SusSVN/sus/trunk/OPOS/H1/OPO/SAGM1/Data

2024-01-20_2350_H1SUSOPO_M1_WhiteNoise_L_0p02to50Hz.xml
2024-01-20_2350_H1SUSOPO_M1_WhiteNoise_P_0p02to50Hz.xml
2024-01-20_2350_H1SUSOPO_M1_WhiteNoise_R_0p02to50Hz.xml
2024-01-20_2350_H1SUSOPO_M1_WhiteNoise_T_0p02to50Hz.xml
2024-01-20_2350_H1SUSOPO_M1_WhiteNoise_V_0p02to50Hz.xml
2024-01-20_2350_H1SUSOPO_M1_WhiteNoise_Y_0p02to50Hz.xml

ZM5

/ligo/svncommon/SusSVN/sus/trunk/HXDS/H1/ZM5/SAGM1/Data

2024-01-20_2340_H1SUSZM5_M1_WhiteNoise_L_0p01to50Hz.xml
2024-01-20_2340_H1SUSZM5_M1_WhiteNoise_P_0p01to50Hz.xml
2024-01-20_2340_H1SUSZM5_M1_WhiteNoise_Y_0p01to50Hz.xml

ZM4

/ligo/svncommon/SusSVN/sus/trunk/HXDS/H1/ZM4/SAGM1/Data

2024-01-20_2330_H1SUSZM4_M1_WhiteNoise_L_0p01to50Hz.xml
2024-01-20_2330_H1SUSZM4_M1_WhiteNoise_P_0p01to50Hz.xml
2024-01-20_2330_H1SUSZM4_M1_WhiteNoise_Y_0p01to50Hz.xml

ZM3

/ligo/svncommon/SusSVN/sus/trunk/HXDS/H1/ZM3/SAGM1/Data

2024-01-20_2320_H1SUSZM3_M1_WhiteNoise_L_0p01to50Hz.xml
2024-01-20_2320_H1SUSZM3_M1_WhiteNoise_P_0p01to50Hz.xml
2024-01-20_2320_H1SUSZM3_M1_WhiteNoise_Y_0p01to50Hz.xml

ZM2

/ligo/svncommon/SusSVN/sus/trunk/HXDS/H1/ZM2/SAGM1/Data

2024-01-20_2320_H1SUSZM2_M1_WhiteNoise_L_0p01to50Hz.xml
2024-01-20_2320_H1SUSZM2_M1_WhiteNoise_P_0p01to50Hz.xml
2024-01-20_2320_H1SUSZM2_M1_WhiteNoise_Y_0p01to50Hz.xml

ZM1

/ligo/svncommon/SusSVN/sus/trunk/HXDS/H1/ZM1/SAGM1/Data

2024-01-20_2310_H1SUSZM1_M1_WhiteNoise_L_0p02to50Hz.xml
2024-01-20_2310_H1SUSZM1_M1_WhiteNoise_P_0p02to50Hz.xml
2024-01-20_2310_H1SUSZM1_M1_WhiteNoise_Y_0p02to50Hz.xml

HSTS (FC1)

/ligo/svncommon/SusSVN/sus/trunk/HSTS/H1/FC1/SAGM1/Data

2024-01-20_2300_H1SUSFC1_M1_WhiteNoise_L_0p02to50Hz.xml
2024-01-20_2300_H1SUSFC1_M1_WhiteNoise_P_0p02to50Hz.xml
2024-01-20_2300_H1SUSFC1_M1_WhiteNoise_R_0p02to50Hz.xml
2024-01-20_2300_H1SUSFC1_M1_WhiteNoise_T_0p02to50Hz.xml
2024-01-20_2300_H1SUSFC1_M1_WhiteNoise_V_0p02to50Hz.xml
2024-01-20_2300_H1SUSFC1_M1_WhiteNoise_Y_0p02to50Hz.xml

The suspensions were set to ALIGNED state after the measurements were complete.

Non-image files attached to this report
Comments related to this report
rahul.kumar@LIGO.ORG - 18:48, Sunday 21 January 2024 (75493)SEI, SUS

Also, when I logged in on Saturday morning I found the seismic watchdogs of HAM7 chamber to be tripped. I did a reset and sent a text message to Jim. During the measurements the WD tripped again (perhaps due to too much suspension excitation?). I left the ISI to be in damped state.

rahul.kumar@LIGO.ORG - 18:52, Sunday 21 January 2024 (75494)

Dave, Rahul (HAM6 saturations)

I had plans to perform similar measurements in HAM6, however this was not possible due to very strong purge air causing the suspensions to saturate (lots of ADC overflows and WD tripping on OM1). There was also an FPU error, which as per Dave was also caused due to the overflows.

I am planning to perform this measurement on Monday morning once the purge air flow is reduced.

Displaying report 1-1 of 1.