Characterization of the spare OMC DCPD Whitening Chassis - S2300002

JeffK, FranciscoL [LouisD remote]

Finished characterizing the spare OMC DCPD whitening chassis (D2200215), S2300002.

Noise is matching the expected performance. Transfer Functions look normal.

A fit of the TF data is pending and will be added as a comment.

Non-image files attached to this report
Comments related to this report
louis.dartez@LIGO.ORG - 09:45, Tuesday 28 May 2024 (78072)
Here are the zpk fits for the OMC DCPD data. The PDF Report is attached. 

OMC DCPD A:
   Whitening ON: 
      zeros: [0.993694] Hz
      poles: [4.467514e+04 9.871288e+00] Hz
   Whitening OFF:
      zeros: [] Hz
      poles: [44628.188186] Hz

OMC DCPD B:
   Whitening ON:
      zeros: [1.002049] Hz
      poles: [4.474433e+04 9.956902e+00] Hz
   Whitening OFF:
      zeros: [] Hz
      poles: [44711.662211] Hz

The raw output is stored at [CalSVN]/trunk/Common/Electronics/H1/DCPDWhitening/OMCA/S2300002/20240523/Results/.