sheila.dwyer@LIGO.ORG - posted 12:47, Monday 21 November 2016 (31691)
another case of scatter involving tip tilts

We had another incident of the kind of scattering that was investigated in 30790 and comments, and in 31267

We see peaks in DARM that are probably upconversion of the 6.1Hz tip tilt resonaonces. 

Over the weekend I had turned off the cut off of DC1Y, which actuates on both RMs.  I rengaged this and the loops still seem stable, but it didn't have a repeateable impact on the noise.  

Images attached to this report
H1 ISC (OpsInfo)
jim.warner@LIGO.ORG - posted 12:31, Monday 21 November 2016 (31690)
Change to a Violin mode damping setting in ISC_LOCK

I've noticed in the last couple of long locks that Mode 7 on ETMY slowly rings up. I mentioned it in log 31000, Cheryl did in 31657. With Jenne's ok, I've increased the gain in Violin_mode_2 to -24, from -20 in ISC_LOCK and loaded the new code. Cheryl went all the way to -60 in her log, so we clearly have some head room. I'll watch over the rest of my shift to see if this seems stable, but it's working well so far.

H1 CDS (DAQ)
david.barker@LIGO.ORG - posted 12:03, Monday 21 November 2016 (31689)
CDS ER10 Summary, Thursday 17th - Sunday 20th November 2016

model restarts logged for Thu 17/Nov/2016 - Sun 20/Nov/2016 No restarts reported.

DAQ - stable (running 6 days). fw0 has with older version of frame-cpp (will be updated 11/22/2016). No critical problems reported.

H1 PEM
jeffrey.bartlett@LIGO.ORG - posted 11:46, Monday 21 November 2016 (31688)
Mothly Dust Monitor Vacuum Pump Check (FAMIS #7507)
   All vacuum pumps are running within specified pressure and temperature ranges. Made a small adjustment to the End-Y vacuum pressure. Closed FAMIS #7507.
H1 DetChar
laura.nuttall@LIGO.ORG - posted 11:03, Monday 21 November 2016 (31685)
Data Quality Shift Thurs 17th - Sun 20th Nov

Jess McIver, Laura Nuttall

The full DQ shift can be found on the detchar wiki. Here are the highlights:

* Two long, in excess of a day, lock stretches with ranges around 70 Mpc
* Range drops could be beam alignment drift
* Whistles appeared in the two short lock stretches on Friday. Spotted using hveto which found a good coincidence with POP 9
* Ran bruco on a lock stretch where the 1083 Hz Cal line was turned off to see if there are any coherences around 1080Hz glitchy region. Nothing particularly obvious

Separate alogs will follow about more follow up during this shift 

H1 CAL
jeffrey.kissel@LIGO.ORG - posted 10:07, Monday 21 November 2016 (31667)
Calibration Update Process Interrupted by EQ
J. Kissel, K. Izumi, D. Tuyenbayev 

We were just about to use a new sweep I took (with data attached) to update the front-end portion of the low-latency calibration pipeline during the ~30 hour lock stretch, but we were rudely interrupted by a 6.4 [mag] EQ in Argentina. Thus we have not yet updated the calibration. We will resume tomorrow morning when we are on site and can get a before and after change set of measurements.

Things on the plate to update:
(1) DC actuation strength, based on results from frequency-dependent sweeps of each actuation stage and the long-duration, single frequency measurements taken in the first few weeks of ER10. We expect the TST and UIM stage to receive updates on the level of a few percent. We expect this will increase the BNS range a bit.
(2) The frequency dependence of all stages of the actuator. This is to account for optical lever damping, and newly included UIM violin mode resonances. We do not expect this to affect the BNS range.
(3) Small adjustments to the inverse sensing function to get updated values for the optical gain (will likely be ~3% higher). We expect this to decrease the BNS range a bit.
(4) EPICs records that store the DARM loop model at calibration line frequencies to match the reference measurement times.

Unfortunately, its only after we make these updates will we be able to trust any of the time-dependent tracking system.

All this being said, the current sensing function sweep (retaken today) sweep shows that the PCAL is discrepant with DELTAL external by 5% (though this changes with time as the TST actuation strength, optical gain, SRC detuning, and cavity pole change). However, we think we can reduce this systematic offset by making the above updates. 

The strange thing, is that the fit RSE cavity pole and SRC detuned spring freq are statistically different than what has been measured to-date. I'm worried this has to do with Shiela's finalizing the alignment configuration to get back onto REFL WFS (see LHO aLOG 31653).


                                 [Units]  value(95% c.i.)

Meas Date                 2016            Nov 20        
IFO Input Power                  [W]      29.1          
SRC1 Loop Status                          ON            

Optical Gain              x 1e6  [ct/m]   1.15 (0.002)
DARM/RSE Cav. Pole Freq.         [Hz]     353.5(6.0)
Detuned SRC Optical Spring Freq. [Hz]     7.02 (0.3)   
Optical Spring Q-Factor (1/Q)    []       0.04 (0.01)  
Residual Time Delay              [us]     2.4  (5.4)   
 
aLOG                                      this aLOG 

Details:

CalSVN repo root: [~] = /ligo/svncommon/CalSVN/aligocalibration/

Data lives here:
[~]/trunk/Runs/ER10/H1/Measurements/
DARMOLGTFs/2016-11-20_H1_DARM_OLGTF_4to1200Hz_fasttemplate.xml
PCAL/2016-11-20_H1_PCAL2DARMTF_4to1200Hz_fasttemplate.xml


Analysis produced by running:
[~]/trunk/Runs/ER10/H1/Scripts/PCAL/fitDataToC_20161116.m          Revision: 3815
on each of the measurement config files listed below.

Model Config Files:
[~]/trunk/Runs/ER10/Common/params/IFOindepParams.conf              Revision: 3776
[~]/trunk/Runs/ER10/H1/params/H1params.conf                        Revision: 3811
[~]/trunk/Runs/ER10/H1/params/2016-11-12/H1params_2016-11-12.conf  Revision: 3800

Measurement Config Files:
[~]/trunk/Runs/ER10/H1/params/2016-11-20/measurements_2016-11-20_sensing.conf   Revision: 3821
Images attached to this report
Non-image files attached to this report
H1 PSL
edmond.merilh@LIGO.ORG - posted 10:03, Monday 21 November 2016 - last comment - 10:11, Monday 21 November 2016(31681)
PSL Weekly 10 Day Trends - FAMIS #6123

WeeklyXtal - explanation of what's going on with HPO diode powers is here. Amp diode powers are tracking with humidity, as they do.

WeeklyLaser - everything looks ok. BOXHUM shows decrease.

WeeklyEnv - everything looks ok. Temps and Humidity show decrease.

WeeklyChiller - there is a direct correlation between the Xtal Chiller flow and the OSC Press 1&2. OSC HEADFLOWS all show marginal decreases except for HEAD4 which is either very stable or has a faulty readback?

Images attached to this report
Comments related to this report
jason.oberling@LIGO.ORG - 10:11, Monday 21 November 2016 (31683)

Head 4 was part of the group of faulty flow sensors (FE flow, PowerMeter flow, and Head 4) that were causing our interlock trips.  These were bypassed in the Beckhoff software (alogged by Peter here); the variables were forced so the readback from the sensors is being ignored.  Due to time constraints between commissioning, readiness for ER10 and now transistioning to O2, these bypasses are being left in place until after O2.  We still have active flow sensors to give us protection in the case of a real flow fault.

Everything else looks as expected.

H1 PSL
jim.warner@LIGO.ORG - posted 09:46, Monday 21 November 2016 (31682)
PSL Weekly Status

Laser Status:
SysStat is good
Front End power is 34.539993463W (should be around 30 W)
Frontend Watch is GREEN
HPO Watch is GREEN

PMC:
It has been locked 4.0 days, 13.0 hr 15.0 minutes (should be days/weeks)
Reflected power is 12.7175809387 Watts and PowerSum = 74.0388560218 Watts.

FSS:
It has been locked for 0.0 days 8.0 h and 2.0 min (should be days/weeks)
TPD[V] = 3.54349908377V (min 0.9V)

ISS:
The diffracted power is around 5.1059646249% (should be 5-9%)
Last saturation event was 0.0 days 8.0 hours and 1.0 minutes ago (should be days/weeks)


Possible Issues:
(Be sure to look into these, as they will not be printed in the report)
PMC reflected power is high
 

H1 ISC (SEI)
hugh.radkins@LIGO.ORG - posted 09:09, Monday 21 November 2016 - last comment - 18:53, Monday 28 November 2016(31679)
TIDAL RED TRIGGER RESET Discussion

On Thursday we (Sheila, Daniel & I) increased the Thresholds on the TIDAL RED TRIGGER when the very low value kept the ISC driving the HEPI too long.  It would appear there was only one long lock stretch with these settings before Sheila reported that the tidal was not coming on, in some locks.  Beam diverters?...  When Nutsinee reverted the values of the RED TRIGGER Thresholds, things seemed to start working properly again.  I don't pretend to understand this and it is pretty clear that reverting the values solved the problem.  See attached four days trend, when lowering the THRESH_ON value started the TIDAL running (I did not zoom in but it looks correlated.) But also seen is the REDTRIG_INMON has dropped to 153000 from the previous 165000.  If this level (Power?) change was enough to disable the 8000 count THRESH_ON setting, clearly something else must be in play.  I need to understand the triggering better to really understand this.  We don't want the ISI to trip as it can be several minutes for the T240s to settle and be ready for complete ISI isolation but obviously we need the TIDAL relief to engage.

Images attached to this report
Comments related to this report
daniel.sigg@LIGO.ORG - 10:47, Monday 21 November 2016 (31684)

It might be that the threshold wasn't exceeded, when it tried to engage REDLOCK. The fundamental problem is that neither the arm power nor the trigger thresholds are getting scaled with the power up, so the threshold needs to be set low enough to catch the lock at low power. Once you power up, the arm powers will then be far above threshold. Too much it seems. Probably best to figure out how to scale the NSUM value with the inverse of the input power. Alternatively, one could rewrite the trigger so that it scales automatically.

jeffrey.kissel@LIGO.ORG - 18:53, Monday 28 November 2016 (31944)
Opened FRS Ticket 6787. 
This has happened a few more times this evening.
H1 General
nutsinee.kijbunchoo@LIGO.ORG - posted 08:02, Monday 21 November 2016 - last comment - 21:03, Monday 21 November 2016(31678)
Ops Owl Shift Summary

TITLE: 11/21 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC

STATE of H1: Observing

INCOMING OPERATOR: Jim

SHIFT SUMMARY: One lockloss during the shift. There was a small earthquake in CA showed up on the seismic FOM around the same time (read 0.1 um/s). This amplitude of earthquake doesn't usually break the lock so I wonder if something else might have caused it. Had no issue relocking.

LOG:

9:28 Out of Observe to run a2l

9:36 a2l done. Back to Observe.

09:42 Lockloss

10:16 Arrived at NLN. Took time to damp bounce modes and ran a2l.

10:31 Observe

13:07 Out of Observe to run a2l

13:12 Observe

15:13 Out of Observe, ran a2l

15:18 back to Observe.

 

Dust alarm and Vacuum alarm (CP4) continues to beep. If your system is using the alarm handler please make sure the threshold is set right and only make it beeps when things are critical. Otherwise operators are just going to keep ignoring these alarms, including the ones that might actually be critical.

Comments related to this report
jeffrey.bartlett@LIGO.ORG - 13:16, Monday 21 November 2016 (31692)
  Checked the alarm level settings for all site dust monitors, and all are set correctly.
  Dust monitor alarms should be investigated and documented in the aLOG. Use some common sense when aLOGing an event, e.g. if you know Karen is cleaning at End-? and the alarm goes off no need to log. All unknown alarms should be logged. 
H1 General
cheryl.vorvick@LIGO.ORG - posted 00:07, Monday 21 November 2016 (31676)
OPS Eve Shift Summary:

State of H1: locked in NLN, PR3 on POP WFS, in Observe

Commissioners: Kiwamu, Darkhan

Activities:

H1 SUS (SUS)
cheryl.vorvick@LIGO.ORG - posted 23:48, Sunday 20 November 2016 - last comment - 16:03, Monday 21 November 2016(31675)
ITMY appears to be swinging in pitch at 0.55Hz thoughout H1 locks

Maybe this is known, but I didn't find an alog showing this feature of ITMY.

Plot 1: ITMY

OSEMs LF and RT have a peak at 0.55Hz throughout the long lock yesterday, T0 = 11/19, 16:00UTC, 750 averages

The peak in the LF and RT OSEMs seems to suggest the optic is swinging at 0.55Hz in pitch all the time, and that that swinging gets kicked up at lock loss.

Plot 2: ITMY, ITMX, ETMY, ETMX, OSEMs LF and RT, all optics

The peak at 0.55Hz in OSEMs LF and RT is unique to ITMY.

Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 09:21, Monday 21 November 2016 (31680)OpsInfo
It's not really helpful, because we don't yet have a solution, but here's the aLOG where this problem has been explored: LHO aLOG 31404. I have no suggestions as of yet on how to fix it, other than re-designing the loops to add more gain (read: *any* gain) at this frequency.

Hugh is studying how far back in time this problem has persisted (it's been a problem since at *least* Oct 28), in hopes to find some sort of coincident hardware/electronics activity to blame. But so far, no dice.
sheila.dwyer@LIGO.ORG - 16:03, Monday 21 November 2016 (31701)OpsInfo

Jeff K, Sheila, Jenne, Evan

While we were having an EQ, we took a quick look at what is wrong with ITMY.  

Since Cheryl pointed out that this motion is seen in LF and RT, we became suspicous of a problem with top mass V and R damping.  Indeed, there was a "bounce" filter engaged in ITMY top mass V damping which must have been a mistake.  Once we turned this off the OLTF of the vertical damping looks verry similar between ITMX and ITMY.  With this filter on ITMY damping was garbage.  

I accepted the change in SDF. We also noticed while doing this that the top mass actuator state for ITMX was 1, while the rest of the quads were in state 2, so we switched that.  The large peak at 0.55 Hz that Cheryl aloged is gone now, and hopefully we won't have the problem with long long ringdowns on ITMY. 

Images attached to this comment
H1 General
jim.warner@LIGO.ORG - posted 16:04, Sunday 20 November 2016 - last comment - 23:39, Sunday 20 November 2016(31669)
Shift Summary

TITLE: 11/20 Day Shift: 16:00-24:00 UTC

STATE of H1: Observing

SHIFT SUMMARY:  Lost a 30 hour lock from an earthquake. Jeff, Kiwamu and Darkhan were here doing calibration stuff. Having problems relocking, can't get past noise-tunings. ITMY swing continues to annoy after lock losses.

20:00 Jeff and crew start calibration measurements

21:00 6.4 earthquake in Argentina breaks lock

21:30 Corey brings a tour through

22:00 Robert in and out of LVEA, setting up PEM injections

Comments related to this report
kiwamu.izumi@LIGO.ORG - 19:26, Sunday 20 November 2016 (31672)

Cheryl, Kiwamu,

Executing each line of NOISE_TUNINGS, we spotted typo in which MICH FF and SRCL FF1 were selecting a wrong set of digital filters. In particular, MICHFF was the worst -- it didn't use the AC coupling filter, resulting in a jolt to ITMs. We set them to the ones that had been used in the previous 30 hour lock stretch (31653). Cheryl will test this to see if the situation is better.

sheila.dwyer@LIGO.ORG - 23:39, Sunday 20 November 2016 (31674)
Sorry that was my mistake.
LHO VE
kyle.ryan@LIGO.ORG - posted 08:01, Sunday 20 November 2016 - last comment - 19:44, Sunday 20 November 2016(31661)
Annulus ion pump out of range
Can't id exact unit remotely or from memory but think this is on the Diagonal Volume.  I think that all AIPs on the diagonal are low hour so hopefully this will be an easy electronics swap? 

Comments related to this report
john.worden@LIGO.ORG - 09:31, Sunday 20 November 2016 (31663)

This one is labeled IBM AIP 192 (also LY-IBM)  - perhaps the 2K input MC tube?? Did we mislabel these?

The other red one is HAM12 on the 2K volume.

Images attached to this comment
chandra.romel@LIGO.ORG - 19:44, Sunday 20 November 2016 (31673)

The one labeled IBM is on 2K volume, but there is no pump connected to annulus volume right now, which is why it's been red on vacuum GUI. That volume was pumped down and capped off at a valve. HAM 12 on vacuum GUI is actually HAM 11 (same with HAM7/8). We should fix wiring so they read right.

H1 CDS (CDS, DetChar)
sheila.dwyer@LIGO.ORG - posted 17:57, Saturday 19 November 2016 - last comment - 12:28, Wednesday 23 November 2016(31651)
RF incident?

It looks like we had another incident of the POP90 power changing, (circled in the striptool screenshot) similar to what Stefan described in 31181.  Is this still a problem with the demod as RIchard found the first time?  If its only an intermittent problem with the POPAIR 90 demod, we probably don't need to worry about fixing it before O2 because that is jiust a monitor and won't be used if we are able to close the beam diverters for the run.  

Detchar question: 

Did we have RF45 glitches around these times?  The times are roughly 16:26, 16:30, 16:36 and 16:42 Nov 19th local time, which is 0:26, 0:30, ect Nov 20th UTC time.  

Images attached to this report
Comments related to this report
richard.mccarthy@LIGO.ORG - 11:46, Sunday 20 November 2016 (31666)
We were able to fix some obvious problems with this but the problem with the shield was not changed as we did not test it after the fact.  Though this problem should only appear if someone was in the rack.  
Would be interesting to see if anything is on 9,or 45MHz
laura.nuttall@LIGO.ORG - 11:18, Monday 21 November 2016 (31686)

I took at look at the auiliary channels we used to create DQ flags monitoring RF45 noise in O1, namely H1:LSC-MOD_RF45_AM_CTRL_OUT_DQ and H1:ASC-AS_B_RF36_I_YAW_OUT_DQ. I created BLRMS of these channels in the same way we did in O1 to threshold on. In all of these plots we see a steady BLRMS over 21 hours from 20th Nov 00:00 - 21:00 UTC, indicating that these channels do not see any form of RF45 noise we are used to:

* Plot 1 - BLRMS of H1:LSC-MOD_RF45_AM_CTRL_OUT_DQ between 10-100Hz in 60 seconds strides
* Plot 2 - BLRMS of H1:LSC-MOD_RF45_AM_CTRL_OUT_DQ between 10-100Hz in 1 second strides
* Plot 3 - BLRMS of H1:ASC-AS_B_RF36_I_YAW_OUT_DQ between 30-170Hz in 1 second strides

Hveto for this day indicated that H1:ASC-AS_A_RF45_Q_PIT_OUT_DQ was a good channel to veto noise with on Sunday. I therefore did a BLRMS of this channel:

* Plot 4 - BLRMS of H1:ASC-AS_A_RF45_Q_PIT_OUT_DQ between 5-100 Hz in 1 second strides

This channel does show excess noise at certain times of the day. If we were to threshold on this BLRMS using the 99.5% BLRMS value during this time period, we would capture the times Sheila mentions and also veto 8/10 top ten pycbc live triggers for this day. 

Not conclusive that this noise is RF45 noise similar to what we saw in O1, investigating further...

Images attached to this comment
evan.hall@LIGO.ORG - 12:28, Wednesday 23 November 2016 (31786)

Seemingly another incident: circa 2016-11-23 20:25:30 Z.

H1 CAL (CAL)
jeffrey.kissel@LIGO.ORG - posted 11:06, Friday 18 November 2016 - last comment - 03:46, Monday 21 November 2016(31601)
Fourth Round of ER10 Calibration Measurements Complete -- Second at 30 W
J. Kissel, D. Tuyenbayev

Darkhan and I was able to get another round of calibration sweeps in last night, just after Sheila finished up her alignment test (LHO aLOG 31599). This set is at 31.92 W, with SRC1 Loops Closed -- and the second set of data with the anticipated O2 configuration.

Datasets live here: 
Sensing Function:
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER10/H1/Measurements/DARMOLGTFs
2016-11-17_H1_DARM_OLGTF_4to1200Hz_fasttemplate.xml
/ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/ER10/H1/Measurements/PCAL
2016-11-17_H1_PCAL2DARMTF_4to1200Hz_fasttemplate.xml

Actuation Functions
2016-11-17_H1SUSETMY_L1_iEXC2DARM.xml
2016-11-17_H1SUSETMY_L1_PCAL2DARM.xml
2016-11-17_H1SUSETMY_L2_iEXC2DARM.xml
2016-11-17_H1SUSETMY_L2_PCAL2DARM.xml
2016-11-17_H1SUSETMY_L3_iEXC2DARM.xml
2016-11-17_H1SUSETMY_L3_PCAL2DARM.xml


I'd found that I'd stored the wrong channels in my new templates for the exploration of the UIM/L1 high frequency actuation on 2016-11-12 (LHO aLOG 31433), so I repeated those measurements as well storing the right channels this time:
2016-11-17_H1SUSETMY_L1_iEXC2DARM_HFDynamicsTest_100-250Hz.xml
2016-11-17_H1SUSETMY_L1_iEXC2DARM_HFDynamicsTest_250-350Hz.xml
2016-11-17_H1SUSETMY_L1_iEXC2DARM_HFDynamicsTest_300-500Hz.xml
2016-11-17_H1SUSETMY_L1_iEXC2DARM_HFDynamicsTest_90-400Hz_SweptSine.xml
2016-11-17_H1SUSETMY_L1_PCAL2DARM_HFDynamicsTest_100-250Hz.xml
2016-11-17_H1SUSETMY_L1_PCAL2DARM_HFDynamicsTest_250-350Hz.xml
2016-11-17_H1SUSETMY_L1_PCAL2DARM_HFDynamicsTest_300-500Hz.xml
2016-11-17_H1SUSETMY_L1_PCAL2DARM_HFDynamicsTest_90-400Hz_SweptSine.xml

Analysis will be posted today (it's finished, we now just need to document it all), and we plan on updating the DARM model and front-end calibration by Monday.
Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 12:50, Friday 18 November 2016 (31609)CAL, CSWG, DetChar, SUS
The high-frequency dynamics measurements quoted in this aLOG have been analyzed. See results in LHO aLOG 31603.
darkhan.tuyenbayev@LIGO.ORG - 18:14, Saturday 19 November 2016 (31649)CAL

J. Kissel, K. Izumi, D. Tuyenbayev,

Overview

Actuation strengths [N/ct] for all three stages have been calculated with MCMC method. In In this analysis we used data from last set of measurements taken on Nov 17 (see above), together with measurements from Nov 7, 8, 10 and 12 (see LHO alogs 31303, 31371, 31403, 31433). The calculated actuation coefficients are:

KU = 8.1648-8 N/ct

KP = 6.844-10 N/ct

KT = 4.395-12 N/ct

The H1DARM model parameters were updated using these values, particularty:

UIM_NpA = 1.739; [N/A]
PUM_NpA = 0.0334; [N/A]
TST_NpV2_y = 1.612e-10; [N/V^2]

We will double check the overall DARM loop model, with the updated sensing and actuation, by comparing it to DARM loop TF measurements.

Notice that TST actuation coef came out as a negative quantity, we believe that there is a "-1" missing in the model of this stage.

Details

For this analysis we took each actuation stage to DARM TF and PCALY to DARM TF measurements at the same frequency vector and used only data points with coherences above 0.9, we adopted a Matlab script used at LLO for this part of the analysis (see EvanG's LLO alog 29438). For each actuation stage i, the test point excitation to DARM TF is

iEXC2DARM = Ai,meas * C / (1 + G)

and PCALY to DARM is

PCALY2DARM = C / (1 + G)

The ratio of the two gives:

iEXC2DARM / PCALY2DARM = Ai,meas

Then we divided this my the model of the given stage without the N/ct coefficient, Ai,model / Ki,model = Fi,model, gives measurement of the frequency-independent N/ct coefficient:

Ai,meas / Fi,model = Ki,meas

Then, we used GWMCMC library (https://github.com/grinsted/gwmcmc) for fitting amplitude and phase of the N/ct coefficient for each stage (if the frequency dependent part of the model is correct, then the phase should be 0 deg). The log likelihood function used for fitting is

logLike = log( ∏( 1 / sqrt(2πσi2) exp( - (Ki,meas - Kfit)2/(2σi2) ) )

Fit results for magnitudes are given above and the phases are at the order of 10-3 deg.

The KU, KP and KT coefficients calculated from multiple-frequency transfer function measurements differ from earlier estimations from single line (LHO alog 31344) by 1.7%, 5.3% and 3.1% for UIM, PUM and TST stages. Possibly some unaccounted systematics in the frequency reponses of the DARM model near 35 Hz (the previous analysis was done with the DARM model for ER9).

Non-image files attached to this comment
darkhan.tuyenbayev@LIGO.ORG - 17:47, Sunday 20 November 2016 (31668)CAL

Izumi K, Kissel J, Tuyenbayev D,

We used ER10 model to re-run an earlier actuation strength analysis using calibrartion line data from Nov 3 - Nov 8 (LHO alog 31344). The original analysis was done with the DARM model in which the positive N/ct sign was used for TST stage actuation, the correct KT sign must have been negative. Below we list the updated results from this single-line analysis, the values are taken from GPS time interval [1162369920 1162413500]:

KU = 8.613 × 10-8 ± 3.204 × 10-10 N/ct
KP = 6.802 × 10-10 ± 2.254 × 10-12 N/ct
KT = -4.341 × 10-12 ± 1.339 × 10-14 N/ct

Notice this analysis is used as an additional check of the multiple-frequency analysis (see above). The DARM model parameters for ER10/O2 will be based on the multiple-frequency analysis results (refined numbers and comparison results are coming soon).

Non-image files attached to this comment
darkhan.tuyenbayev@LIGO.ORG - 03:46, Monday 21 November 2016 (31677)CAL

Izumi K, Kissel J, Tuyenbayev D,

Overview

We calculated the actuation coefficients for the H1 DARM reference time model. For UIM (L1) and PUM (L2) stages the N/ct coefficients were fit based on actuation TF measurements on Nov 7, 8, 10, 12 and 15. These numbers have been reported earlier (see above). The TST actuation strength will have a trend over long time period due to charge accumulation, thus for TST stage it is better to estimate the coefficient based on measurements taken within a short period of time. Since we set the reference sensing function parameters based on measurements taken on Nov 12, for estimation of the TST (L3) stage actuation we decided to use measurements around that date, particularly measurements from Nov 10 and 12.

Contributions from each of the actuation stages to the overall DARM response drops as 1/f6, 1/f4 and 1/f2, for this reason MCMC (and LSQ) fitting were restricted to [0 10] Hz, [0 200] Hz and [0, 200] Hz for UIM, PUM and TST stages respectively.

Below are the resulting N/ct values, these values:

KU = 8.1648 × 10-8 N/ct (±  0.074% 1-σ)
KP = 6.844 × 10-10 N/ct (± 0.018% 1-σ)
KT = -4.389 × 10-12 N/ct (± 0.031% 1-σ)

And the H1DARM model were updated in the following way (only the N/V2 for TST stage is different from LHO alog 31649):

UIM_NpA = 1.739;         % [N/A]
PUM_NpA = 0.0334;        % [N/A]
TST_NpV2_y = 1.6097e-10; % [N/V^2]

New EPICS values used for DARM time-dependent parameters have been calculated with the updated H1 DARM model for ER10/O2 (see attachment 1).

Comparisons

MCMC and LSQ methods gave consistent results, fractional discrepancies between the two were at the order of 10-5 (LSQ fit was done only for magnitude).

Discrepancies between the new values and the ones currently installed in the CAL-CS front-end model are:

UIM: 0.05% (compared 8.1689 × 10-8 N/ct, the currently installed, old value)
PUM: 0.05% (compared to 6.8407 × 10-10 N/ct)
TST: 3.42% (compared to 4.239 × 10-12 N/ct)

Discrepancies between these values and an updated single-line analysis results (see LHO alog 31668 above) are 5.5% (UIM), 0.6% (PUM) and 1.4% (TST). A larger discrepancy between MCMC and the single-line analysis for UIM, we believe, is mostly due to 5-10% systematic errors in the UIM suspension model at ~36 Hz (see a residual plot attached to Kiwamu's LHO alog 31427).*

Although, the TST stage coefficient was calculated based on Nov 10th and 12th measurements, discrepancies between the values estimated for each of the 5 measurements (Nov 7 - 17), are within 0.5% (see attachment 2).

*Check out Jeff's LHO alog 31603 for more UIM HF investigations.

Details

TST stage fitting plots are attached below (see attachments 3 and 4). UIM and PUM fitting results did not change (see previous report above, LHO alog 31609).

The new EPICS values for DARM time-dependent parameters are committed to

${CalSVN}/Runs/ER10/H1/Scripts/CAL_EPICS/D20161120_H1_CAL_EPICS_VALUES.m

The up-to-date H1 DARM model parameters are commited to CalSVN:

${CalSVN}/Runs/ER10/Common/params/IFOindepParams.conf              r3752
${CalSVN}/Runs/ER10/H1/params/H1params.conf                        r3826
${CalSVN}/Runs/ER10/H1/params/2016-11-12/H1params_2016-11-12.conf  r3786

DARM model scripts (SRC detuning TF was modified to include Q-factor at r3814):

${CalSVN}/Runs/O2/DARMmodel/*  r3814

Actuation coefficient fitting script was uploaded to

${CalSVN}/Runs/ER10/H1/Scripts/FullIFOActuatorTFs/fitActCoefs_Npct.m  r3829

And the results are at

${CalSVN}/Runs/ER10/H1/Results/Actuation/2016-11-20_H1_SUSETMY_*.pdf

Non-image files attached to this comment