Reports until 10:49, Tuesday 29 September 2015
H1 CAL (CAL)
darkhan.tuyenbayev@LIGO.ORG - posted 10:49, Tuesday 29 September 2015 - last comment - 15:33, Tuesday 29 September 2015(22056)
Added time advance corrections into the actuation and the sensing functions of the H1 DARM OLG TF model

ShivarajK, JeffreyK, DarkhanT,

Overview

To reduce phase systematics in the DARM OLGTF model we've adjusted time delays/advances in the actuation and the sensing functions of the DARM loop Matlab model.

With the included 15 us of time-advance into the actuation function, the phase residuals of each of the actuation stage TFs up to 100 Hz measured on Aug. 26 - 29 are under 2 deg at high frequencies (except for L1 stage which is about 5 deg, which is ok because at high frequencies we rely mostly on L3 stage actuation), and the overall actuation function rediduals at high frequencies to mostly under 3 deg (Fig. 1).

To reduce sensing function phase residuals we have added 14 us of time-advance, which is similar to the correction introduced into LLO DARM model for O1 (see LLO alog 20894); with this additional time-advance the sensing function phase residual is mostly under 2 deg (Fig. 2).

DARM OLGTF model for O1 with included actuation and sensing function time delay/advance corrections have phase redisuals that are mostly under 2 deg (Fig. 4).

For GDS pipeline corrections: time delays in the updated H1 DARM model for O1 are:

Details

In the DARMOLGTF model for O1 we had systematic phase residuals, which we planned to account for by adding time delay/advances into the actuation and the sensing functions (see LHO alog 21827). In the H1DARM model for O1 we implemented the time delay/advance correction capability via par.t.unknown_actuation and par.t.unknown_sensing parameters. After that we revisited actuation function stages' redisuals by looking at the plots produced using cmpActCoeffs_viaPcal_O1.m and analyze_pcal_20150928.m (this is a modified version of a script used at LLO, analyze_pcal_20150903.m, see LLO alog 20894), and confirmed that actuation stages with the included 15 us time advance correction show <2 deg residuals (under 5 deg for L1), Fig. 5, 6, 7; we still have ~ 2 % systematic residual in actuation magnitudes that we are leaving unchanged in the Matlab DARM model and the CAL-CS front-end filter modules (Fig. 8, 9, 10).

We modified "H1DARMparams_1125963332.m", "H1DARMparams_1127083151.m" and their kappa corrected versions and re-run CompareDARMOLGTFs_01.m.1 Comparison plots show that:

1we used kappa values at the measurement times from previous calculations (see LHO alog 21827); for the ~30 Hz lines these values shouldn't be too much different from the ones calculated using EP1-9 from the updated O1 model.

H1 DARM model for O1 and comparison script were committed to calibration SVN (r1550)

CalSVN/Runs/O1/H1/Scripts/DARMOLGTFs/H1DARMOLGTFmodel_O1.m

CalSVN/Runs/O1/H1/Scripts/DARMOLGTFs/CompareDARMOLGTFs_O1.m

All of the parameter files in the same directory were modified to include time advances noted in this report.

Actuation function analysis scripts were committed to (r1550) (PCAL parameter files, that were copied from ER8 directory have been also committed into the same directory):

CalSVN/Runs/O1/H1/Scripts/PCAL/analyze_pcal_20150928.m

CalSVN/Runs/O1/H1/Scripts/PCAL/cmpActCoeffs_viaPcal_O1.m

Actuation function analysis plots were committed to (r1551)

CalSVN/Runs/O1/H1/Results/PCAL/2015-09-28_cmpActCoeffs_PCAL_*.pdf

Model comparison plots were committed to

CalSVN/Runs/O1/H1/Results/DARMOLGTFs/2015-09-28_H1DARM_ER8O1_cmp_*.pdf

Non-image files attached to this report
Comments related to this report
darkhan.tuyenbayev@LIGO.ORG - 12:03, Tuesday 29 September 2015 (22065)

We've updated Epics values for the DARM time dependent parameter estimations with the values from the H1 DARM OLG TF model using H1DARMparams_1125963332.m (r1550) parameter file (WP 5510, was filed on Sep 21). This values can be used for recalibration of the GDS_CALIB_STRAIN between Sep 10 and now.

New EP1-9 values are listed in D20150929_H1_CAL_EPICS_VALUES.m and in a more verbose form in 20150929_H1_CAL_EPICS_verbose.txt (old values are also listed at the end of the verbose output).

We've committed the logs for calculating EP1-9 into calibration SVN (r1553)

CalSVN/Runs/O1/H1/Scripts/CAL_EPICS/20150929_H1_CAL_EPICS_VALUES.txt
CalSVN/Runs/O1/H1/Scripts/CAL_EPICS/20150929_H1_CAL_EPICS_verbose.log
CalSVN/Runs/O1/H1/Scripts/CAL_EPICS/D20150929_H1_CAL_EPICS_VALUES.m

New Epics values were accepted in SDF_OVERVIEW, however some of the values still show difference (values with magnitudes less than 10-17).

Images attached to this comment
Non-image files attached to this comment
darkhan.tuyenbayev@LIGO.ORG - 13:49, Tuesday 29 September 2015 (22071)CAL

Sudarshan, Darkhan,

We've re-generated DARM loop model comparison plots with the kappas calculated using most recent EP# values.

  • κtst and κC corrected model actuation function residuals in magnitude are mostly <2 % and in phase are mostly < 2 deg; fully corrected model (red trace) show smaller phase residual at low frequencies (κpu has more effect at low frequencies);
  • κtst and κC corrected model sensing function residuals in magnitude are mostly <2 % (slightly larger at high frequencies) and in phase are mostly <2 deg; fully corrected model show smaller magnitude residual at high frequencies;
  • kappa corrected DARM OLGTF measurement vs. model residuals in magnitude are ~2 % (systematic) and in phase are mostly <2 deg;

"kappas" for this analysis were calculated from the calibration lines within 2 hours from each of the DARM OLGTF measurements.

For Sep 10 (O1 model) measurement the mean kappas from 30 min time interval starting at GPS 1125970532:

κtst = 1.036441
κpu = 1.025962
κA = 1.029902
κC = 1.005923
fc = 339.272371 [Hz]

for Sep 23 measurement the mean kappas from 30 min time interval starting at GPS 1127081351:

κtst = 1.045246
κpu = 1.022774
κA = 1.031924
κC = 1.007507
fc = 332.429690 [Hz]

Non-image files attached to this comment
betsy.weaver@LIGO.ORG - 14:47, Tuesday 29 September 2015 (22079)

I hand edited the h1calcs_OBSERVE.snap to make these diffs go away.  OBSERVE.snap copied to h1calcs_safe.snap.

sudarshan.karki@LIGO.ORG - 15:33, Tuesday 29 September 2015 (22082)

The trend of the time-varying calibration parameters is attached below. These are the values obtained after using the latest epics valuesmentioned in the alog above.

Images attached to this comment