Reports until 11:06, Monday 25 October 2021
H1 AWC (AWC, ISC, SQZ, SUS)
lee.mcculler@LIGO.ORG - posted 11:06, Monday 25 October 2021 - last comment - 11:06, Monday 25 October 2021(60377)
Analysis of ZM4/ZM5 PSAMS beam scans

Following up on the data reported in LHO-60358 and LHO-60356, here I am comparing the beam profiles and inferred defocus as the PSAMS PZT voltage is scanned, for comparison to previous data from the Caltech Zygo and strain gauges. Yes, I am agonizing over 1% level mode matching.

First is a check of the beam profile towards ZM4 from the OPOS. ZM4ZM5.pdf. Shows the data from LHO-60356 in the ZM4scan and then propagated with the 105mD of ZM4 at 0V measured in E2100289. ZM5 shows the scan taken after ZM4 and assuming the 105mD, and they align well. The SQZIFO/MM_L1 is the mode scan of B:L1 from the optics lab in LHO-59036, it is propagated through B:L2 and off of the platform, and it matches with the HAM7 data. The beam target is projected from the interferometer cavity modes for reference and it has an overlap of 99.2% with these scans. Notably, the beam size on ZM4 (and thus ZM5) is a bit smaller than nominal. This can be corrected using ZM4 PSAMS to expand the beam onto ZM5 and then ZM5 to fix the divergence angle.

We took beam scans with a pickoff before ZM5 to determine the ZM4 PSAMS actuation. This is shown in HAM7_beam_profiles.png. It has this associated data table:

  ZM4 PZT [V]    ZM4 strain    diam X [um]    defocus X    diam Y [um]    defocus Y
                  gauge [V]                        [mD]                        [mD]
-------------  ------------  -------------  -----------  -------------  -----------
            0         11.05           3690      113.472           3699      109.233
           30         10.53           3748      132.159           3744      123.701
           60          9.9            3821      155.607           3796      140.383
           80          9.44           3872      171.943           3833      152.228
          100          8.99           3923      188.244           3866      162.777
          116          8.57           3972      203.875           3894      171.717
          100          8.8            3947      195.904           3878      166.61
           80          9.14           3905      182.495           3855      159.263
           60          9.53           3863      169.063           3828      150.629
           30         10.23           3783      143.411           3772      132.688
            0         11.01           3696      115.408           3702      110.198

Note in the figure and in the table, the X data is slightly larger than the Y data at higher voltages, implying a voltage-dependent astigmatism. This isn't so bad on ZM4, as the beam is w~=1mm and the actuator is weak, but this level (30mD) of astigmatism is problematic on ZM2 and ZM5 if it is real. I think actually that our data must have gotten some bias from room lights or being near the edge of the scanner. The main reason for that is that this astigmatism never appeared on the Zygo measurements at CIT. I have been analyzing the ZM mirror data to look for hints of aberration induced by the optic stress. curvatureD_00V.pdf, curvatureD_50V.pdf, curvatureD_110V.pdf show the beam-placement localized astigmatism by convolving the mirror map with the HG modes. In those plots w=2mm rather than ZM4's w=1mm because the resolution is slightly to make good measurements with the realistic beamsize. You see that the astimatism is ~5-10mD, which is characteristic of many of the PSAMS measurements, it also changes very slightly over the PSAMS voltage, but only by 3-5mD, not by 30mD.

 

The second reason to not trust the ZM4 astimatism data is that the second dataset with the beam reflecting from ZM5 is more consistent if you assume the same defocus on ZM4 for X and Y. The data and fits are plotted HAM7_beam_profiles_ZM5.png. They correspond to the data.

  ZM4 PZT [V]    ZM4 strain    ZM4 defocus    ZM4 defocus    ZM5 PZT [V]    ZM5 strain    diam X [um]    ZM5 defocus    diam Y [um]    ZM5 defocus  ZM5 q_X        ZM5 q_Y
                  gauge [V]         X [mD]         Y [mD]                    gauge [V]                        X [mD]                        Y [mD]
-------------  ------------  -------------  -------------  -------------  ------------  -------------  -------------  -------------  -------------  -------------  -------------
            0         11.03            113            109              0         -8.68           1710       -602.213           1681       -607.664  -2.997+1.159i  -2.945+1.122i
            0         11.03            113            109             25         -9.1            1770       -592.113           1744       -597.054  -3.075+1.232i  -3.025+1.196i
            0         11.03            113            109             50         -9.6            1849       -578.927           1815       -585.199  -3.183+1.338i  -3.119+1.286i
            0         11.03            113            109             75        -10.16           1941       -563.708           1900       -571.129  -3.313+1.477i  -3.235+1.406i
            0         11.03            113            109            100        -10.73           2038       -547.797           1993       -555.866  -3.456+1.645i  -3.368+1.555i
            0         11.03            113            109            117        -11.16           2105       -536.877           2061       -544.779  -3.559+1.776i  -3.469+1.678i
            0         11.03            113            109            100        -10.89           2051       -545.674           2016       -552.109  -3.476+1.670i  -3.402+1.596i
            0         11.03            113            109             50         -9.9            1897       -570.969           1853       -578.894  -3.250+1.409i  -3.170+1.338i
            0         11.03            113            109              0         -8.68           1711       -602.044           1683       -607.326  -2.998+1.160i  -2.947+1.125i

And then with ZM4 at its nominal 100V, and not assuming the ZM4 astigmatism.
  ZM4 PZT [V]    ZM4 strain    ZM4 defocus    ZM4 defocus    ZM5 PZT [V]    ZM5 strain    diam X [um]    ZM5 defocus    diam Y [um]    ZM5 defocus  ZM5 q_X        ZM5 q_Y
                  gauge [V]         X [mD]         Y [mD]                    gauge [V]                        X [mD]                        Y [mD]
-------------  ------------  -------------  -------------  -------------  ------------  -------------  -------------  -------------  -------------  -------------  -------------
          100          8.97            168            162              0         -8.68           1821       -602.509           1777       -609.428  -3.143+1.154i  -3.069+1.106i
          100          8.97            168            162             25         -9.08           1875       -593.983           1838       -599.771  -3.217+1.219i  -3.150+1.175i
          100          8.97            168            162             50         -9.62           1960       -580.646           1929       -585.467  -3.338+1.330i  -3.276+1.288i
          100          8.97            168            162             75        -10.16           2052       -566.31            2021       -571.116  -3.477+1.467i  -3.410+1.417i
          100          8.97            168            162            100        -10.74           2158       -549.902           2116       -556.394  -3.645+1.648i  -3.555+1.570i
          100          8.97            168            162            117        -11.15           2230       -538.815           2188       -545.294  -3.765+1.789i  -3.671+1.702i
          100          8.97            168            162            100        -10.89           2183       -546.048           2135       -553.46   -3.686+1.696i  -3.586+1.604i
          100          8.97            168            162             50         -9.9            2006       -573.466           1976       -578.123  -3.407+1.396i  -3.343+1.352i
          100          8.97            168            162              0         -8.68           1823       -602.193           1781       -608.793  -3.145+1.157i  -3.074+1.111i

Then, for comparison, look at the data when astigmatism is assumed.

  ZM4 PZT [V]    ZM4 strain    ZM4 defocus    ZM4 defocus    ZM5 PZT [V]    ZM5 strain    diam X [um]    ZM5 defocus
                  gauge [V]         X [mD]         Y [mD]                    gauge [V]                        X [mD]
-------------  ------------  -------------  -------------  -------------  ------------  -------------  -------------
          100          8.97            188            162             75        -10.16           2052       -573.587
          100          8.97            188            162            100        -10.74           2158       -557.461
          100          8.97            188            162            117        -11.15           2230       -546.562
          100          8.97            188            162            100        -10.89           2183       -553.672

And you see that the ZM5 defocus is not consistent with the ZM4 @ 0V values. Given this, we should perhaps take new pre-ZM4 data.

 

Finally, I projected what this looks like in terms of the interferometer beam. I have my IFO model and can detune the arm and SRC cavities and see the beam parameters walk around. You can choose different reference-planes for those beam parameters.AWCmeshSQZ_SRM.pdf left plots show in brown the SQZ beam parameter immediately after reflecting from the SRM. In addition it shows the X-arm cavity after transmitting through the SRC (plusses) and the SRC cavity mode (crosses). The different colors of those show the effect of different detunings moving the SRC and ARM modes in different directions. The right plot shows the ARM/SRC overlap with the detunings and indicates that most vertex beam detunings have the same effect on the SRC/ARM overlap. The right plots aren't particularly relevant to the ZM4/5 PSAMS.

AWCmeshSQZ_OMC.pdf shows the beams in the plane of the OMC input. My model doesn't have the OMC with exactly perfect overlap to the (nominal) IFO design, but pretty close. This is why the (left plot) contours are not centered on the IFO beams. You can see in both of these plots that the 99.2% overlap with the target is in the direction that is more difficult to correct.

The brown diamonds for the SQZ beam are in a 3x6 grid, with solid lines over the 3 for ZM4 actuation at 0 (115mD), 50 and 100V (165mD) and the dashed go from -605mD to -545mD. These show that the existing 99.2% mismatch is in the direction that requires mostly ZM4 correction and it might barely reach if extended to 200V. We could go ahead and correct for this now by moving or swapping B:L1, but we should perhaps take some SQZ profiles in HAM6 and possibly OMC scans first.

 

I planned to do a bit more with the CIT Zygo measurements in the DCC, so I exported it. Here is that data and the tables above in YAML: ZM4_ZM5_scans.txt and ZM4_ZM5_data.mat. useful for comparing the strain gauges. I notice that the defocus I am measuring is a bit far from what is measured on the ZYGO, particularly for ZM5. There are a few possible places between the PZT drivers and the particulars of these phase maps. It is possible that the local beam-size-scale curvature is smaller than the curvature/sag reported over the entire optic surface, if the sag was used to determine the curvature in the DCC tables.

 

Images attached to this report
Non-image files attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 09:39, Monday 25 October 2021 (60379)ISC, SUS
Tagging SUS and ISC.
lee.mcculler@LIGO.ORG - 10:28, Monday 25 October 2021 (60380)AWC, ISC, SQZ, SUS
Some Q/A from Jeff K:
(1) From where were you reading of the PZT drive high voltage? Off the MEDM screen, i.e. the DC path's voltage readback of the PZT driver, or some raw electrical version via a fluke DVM?
  The PZT drive voltage was read in MEDM using the Beckhoff PZT voltage monitor readback. It has a decent amount of noise on it for some reason, but I should be accurate on the mean to ~1V.
 
(2) How much “warm up” did you give the PZTs before starting your measurement of the range of the PZTs?
Not much immediately before I used them, but they had both popped up to 100V as the HV was turned on. The 0-cnt default output of the HV DAC corresponds to +100V and that was not realized until after power was on. In this case, they only got ~1cycle
 
(3) From where did you readout out the strain gauge voltage? Again, off the ADC?
Georgia added a breakout board to monitor the "SG to Beckhoff" pins out of the PSAMS interface chassis, while also disconnecting them from the Beckhoff ADC. This allowed us to use a fluke to measure the full range above \pm 10V, as the Beckhoff ADC clips not only the voltage that it measures, but also (apparently) goes low impedance and clips its input too, if connected.
 
Bigger picture questions to be resolved over the coming days:
(a) You mention you see some astigmatism. I wonder if these are consistent with the data that Camille took at CIT (i.e. <https://dcc.ligo.org/LIGO-E2100288>)?
I've been in the loop with Camille M. Marie, and Garilynn about that data. Their data is not consistent with astigmatism that large, nor with voltage-dependent astigmatism at that level. This is why I don't believe it in our dataset, but I do want to take more data. More concerning to me is that the common defocus on ZM5 is not what was measured at CIT and indicates a lower range. That we need to track down.